Inadequate control of contractors working on live systems
▶ Training
User awareness training (basic electrical hazards, visual checks)
Training to identify damaged cables, plugs, and equipment
Staff trained to report and isolate faulty items
Competent electrician required for repairs and fixed wiring work
Awareness that water + electrics increase risk
Managers and supervisors trained to monitor cable use and overload risks
▶ Maintenance
User visual checks before use
PAT testing at risk-based intervals (no legal fixed frequency)
Removal of damaged equipment from service immediately
Fixed wiring inspection/report (EICR) by competent electrician — frequency based on risk (commonly 5 years for commercial premises)
Routine checks of sockets, plugs, extension reels, and multi-adapters
Ensure RCD protection where required
Maintenance of emergency lighting and fire alarm circuits
▶ SSOW & Supervision
Remove faulty equipment from service immediately (tag and isolate)
No trailing or damaged cables — maintain tidy cable routing
Do not overload sockets; avoid daisy-chaining
Use correct equipment for damp or wet areas (IP-rated equipment)
Ensure only competent electricians work on installations
Provide RCD protection where reasonably practicable
Clear procedure for reporting and dealing with electrical faults
Supervisors monitor cable use, housekeeping, and condition of appliances
▶ Checklist
Signs of unsafe electrical installation or equipment (e.g. exposed wires, burn marks, overheating, damaged sockets, reports of shocks) EAWR Reg 4(1); Reg 4(2); Reg 6; HSG85 paras 7–10, 12
Electrical equipment or installations appear damaged, poorly maintained or unsafe EAWR Reg 4(2); Reg 6; Reg 16; HSG85 paras 8, 10, 12
Exposed live parts or missing covers on sockets, switches, distribution boards or consumer units EAWR Reg 4(1); Reg 14; HSG85 paras 7, 10, 14
Electrical systems used in conditions likely to cause danger (e.g. damp environments, water ingress, unsuitable equipment for location) EAWR Reg 4(1); Reg 4(3); HSG85 paras 12–13
Distribution boards, fuse boxes or consumer units secure, protected and not obstructed EAWR Reg 4(1); Reg 15; HSG85 paras 10, 15
Means of electrical isolation provided and clearly identifiable EAWR Reg 12; Reg 15; HSG85 paras 15, 47–49
Electrical isolation points accessible and not locked shut or obstructed EAWR Reg 12; Reg 15; HSG85 paras 49–52
Portable electrical equipment appears in good condition (no damaged plugs, cables, joints or casings) EAWR Reg 4(2); Reg 6; HSG85 paras 8, 12
No evidence of unsafe electrical practices (e.g. trailing leads, overloaded sockets, multiple adapters, improvised wiring) EAWR Reg 4(1); Reg 4(3); Reg 16; HSG85 paras 7, 14, 26
Fixed electrical installations appear to be maintained so as to prevent danger EAWR Reg 4(2); Reg 6; HSG85 paras 8–9
Dutyholder able to provide evidence of periodic inspection and testing of fixed electrical installations (e.g. EICR) EAWR Reg 4(2); Reg 6; HSG85 paras 8–9, 18 Note: HSE guidance recognises periodic inspection and testing (commonly every 5 years in many non-domestic premises, or more frequently where risk is higher) as a means of demonstrating compliance.
Evidence of inspection, testing or competent electrician involvement available where appropriate EAWR Reg 4(2); Reg 16; HSG85 paras 18, 40–41
Electrical work appears to be carried out by competent persons (not unqualified staff or DIY) EAWR Reg 16; HSG85 paras 18, 40–41
No evidence of live electrical work being carried out where it could reasonably be avoided EAWR Reg 14; HSG85 paras 23–24
▶ Legal References
HSWA 1974 – s2, s3 (duty to ensure electrical safety)
Slips due to wet floors, spills, cleaning, or contamination (oil, dust, food residue)
Trips from trailing cables, poor housekeeping, or uneven flooring
Falls caused by damaged or poorly maintained floor surfaces
Sudden changes in floor level (steps, thresholds, ramps)
Poor lighting increasing slip and trip risk
Weather-related hazards (rainwater at entrances, ice in yards)
Obstructed walkways or stock stored in aisles
Inadequate footwear for the environment
Injuries to members of the public in shops, gyms, and leisure facilities
▶ Training
Staff training on spill response and immediate reporting
Awareness training on good housekeeping and correct storage
Training on safe cleaning methods and signage use
Induction training covering walkways, PPE, and slip risks
Supervisor training to identify and enforce housekeeping standards
▶ Maintenance
Regular inspections of floors, walkways, stairs, and lighting
Prompt repair of damaged flooring, mats, tiles, and potholes
Maintenance of entrance matting and external surfaces
Review and upkeep of drainage, gutters, and anti-slip coatings
Maintenance of lighting (replace failed lamps promptly)
Regular checks on footwear suitability where provided
▶ SSOW & Supervision
Keep walkways clear and well lit; maintain good housekeeping
Immediate cleanup of spills using proper methods (not spreading contamination)
Use appropriate signage during cleaning and remove when the floor is dry
Control cable routing and avoid trailing leads in walkways
Use suitable entrance matting and manage water ingress during wet weather
Store stock safely to prevent obstructions
Use slip-resistant footwear where risk justifies it
Adjust pace of work to conditions (e.g. kitchens, bars, gyms)
Supervisors monitor compliance with housekeeping and spill procedures
▶ Checklist
Has a suitable and sufficient risk assessment been carried out for slip, trip and fall hazards? MHSWR Reg 3; HSWA ss2–4; INDG225
Does the risk assessment identify foreseeable slip, trip and fall hazards, including floor contamination, uneven surfaces, changes in level and obstructions? MHSWR Reg 3; INDG225
Are floors and traffic routes suitable for the purpose, in good condition and free from holes, unevenness or slippery conditions? Workplace Reg 12; ACOP & INDG225
Are floors kept free from obstructions, trailing cables, waste and materials that could cause trips? Workplace Reg 12(3); HSWA s2
Are spillages and contamination (water, oil, food, dust) prevented so far as reasonably practicable? HSWA s2; INDG225
Where contamination cannot be avoided, are effective control measures in place (e.g. mats, drainage, task design, segregation)? MHSWR Reg 4; INDG225
Are effective arrangements in place for routine cleaning and for dealing promptly with spillages? Workplace Reg 12; INDG225
Are cleaning methods suitable for the type of flooring and do they avoid creating additional slip risks? INDG225
Is flooring suitable for the environment (e.g. slip resistance where floors are likely to become wet)? Workplace Reg 12(2); INDG225
Is lighting suitable and sufficient to allow people to see hazards such as steps, slopes, changes in level and obstructions? Workplace Reg 8
Are steps, stairs, ramps and changes in level clearly visible, in good condition and provided with suitable handrails where required? Workplace Regs 12, 13
Are pedestrian routes appropriately designed, maintained and segregated from vehicles where necessary? Workplace Reg 17; HSWA s2
Is suitable slip-resistant footwear provided or required where floors cannot be kept dry and clean? PPE Regs 1992; HSWA s2; INDG225
Are organisational factors considered, such as work pace, rushing, overcrowding and supervision? MHSWR Reg 3; INDG225
Are employees provided with information and instruction on reporting spillages, defects and near misses? HSWA s2; MHSWR Reg 10
Are slip, trip and fall incidents and near misses reported, recorded and reviewed to identify trends and problem areas? MHSWR Reg 5; HSWA s2
Are control measures reviewed when circumstances change, following incidents, or where monitoring shows they are ineffective? MHSWR Reg 3(3); INDG225