Funeral & Bereavement Services
▶ Risks
- Electric shock from damaged or unsuitable equipment
- Fire from overloaded circuits, faulty wiring, or poor extension lead management
- Contact with live parts (poor guarding, faulty plugs, exposed wiring)
- Use of equipment in wet environments (increased shock risk)
- Trip hazards from trailing cables
- Unsafe use of multi-adaptors or daisy chains
- Damaged lighting circuits, cracked sockets, loose faceplates
- Portable appliances not maintained
- Faulty fixed wiring (old systems, missing RCDs, poorly protected circuits)
- Inadequate control of contractors working on live systems
▶ Training
- User awareness training (basic electrical hazards, visual checks)
- Training to identify damaged cables, plugs, and equipment
- Staff trained to report and isolate faulty items
- Competent electrician required for repairs and fixed wiring work
- Awareness that water + electrics increase risk
- Managers and supervisors trained to monitor cable use and overload risks
▶ Maintenance
- User visual checks before use
- PAT testing at risk-based intervals (no legal fixed frequency)
- Removal of damaged equipment from service immediately
- Fixed wiring inspection/report (EICR) by competent electrician — frequency based on risk (commonly 5 years for commercial premises)
- Routine checks of sockets, plugs, extension reels, and multi-adapters
- Ensure RCD protection where required
- Maintenance of emergency lighting and fire alarm circuits
▶ SSOW & Supervision
- Remove faulty equipment from service immediately (tag and isolate)
- No trailing or damaged cables — maintain tidy cable routing
- Do not overload sockets; avoid daisy-chaining
- Use correct equipment for damp or wet areas (IP-rated equipment)
- Ensure only competent electricians work on installations
- Provide RCD protection where reasonably practicable
- Clear procedure for reporting and dealing with electrical faults
- Supervisors monitor cable use, housekeeping, and condition of appliances
▶ Checklist
- Signs of unsafe electrical installation or equipment (e.g. exposed wires, burn marks, overheating, damaged sockets, reports of shocks)
EAWR Reg 4(1); Reg 4(2); Reg 6; HSG85 paras 7–10, 12 - Electrical equipment or installations appear damaged, poorly maintained or unsafe
EAWR Reg 4(2); Reg 6; Reg 16; HSG85 paras 8, 10, 12 - Exposed live parts or missing covers on sockets, switches, distribution boards or consumer units
EAWR Reg 4(1); Reg 14; HSG85 paras 7, 10, 14 - Electrical systems used in conditions likely to cause danger (e.g. damp environments, water ingress, unsuitable equipment for location)
EAWR Reg 4(1); Reg 4(3); HSG85 paras 12–13 - Distribution boards, fuse boxes or consumer units secure, protected and not obstructed
EAWR Reg 4(1); Reg 15; HSG85 paras 10, 15 - Means of electrical isolation provided and clearly identifiable
EAWR Reg 12; Reg 15; HSG85 paras 15, 47–49 - Electrical isolation points accessible and not locked shut or obstructed
EAWR Reg 12; Reg 15; HSG85 paras 49–52 - Portable electrical equipment appears in good condition (no damaged plugs, cables, joints or casings)
EAWR Reg 4(2); Reg 6; HSG85 paras 8, 12 - No evidence of unsafe electrical practices (e.g. trailing leads, overloaded sockets, multiple adapters, improvised wiring)
EAWR Reg 4(1); Reg 4(3); Reg 16; HSG85 paras 7, 14, 26 - Fixed electrical installations appear to be maintained so as to prevent danger
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9 - Dutyholder able to provide evidence of periodic inspection and testing of fixed electrical installations (e.g. EICR)
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9, 18
Note: HSE guidance recognises periodic inspection and testing (commonly every 5 years in many non-domestic premises, or more frequently where risk is higher) as a means of demonstrating compliance. - Evidence of inspection, testing or competent electrician involvement available where appropriate
EAWR Reg 4(2); Reg 16; HSG85 paras 18, 40–41 - Electrical work appears to be carried out by competent persons (not unqualified staff or DIY)
EAWR Reg 16; HSG85 paras 18, 40–41 - No evidence of live electrical work being carried out where it could reasonably be avoided
EAWR Reg 14; HSG85 paras 23–24
▶ Legal References
- HSWA 1974 – s2, s3 (duty to ensure electrical safety)
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- Electricity at Work Regulations 1989 – Regs 4–16 (core electrical safety duties)
- PUWER 1998 – Reg 4 (suitability), Reg 5 (maintenance), Reg 6 (inspection), Reg 9 (training)
- Workplace (Health, Safety & Welfare) Regs 1992 – Reg 12 (condition of floors/lighting)
- BS 7671 (IET Wiring Regulations) – benchmark for safe fixed installations
- HSE HSG107 & INDG236 – electrical equipment guidance (PAT, user checks)
Risks
- Musculoskeletal injury from lifting, carrying, and manoeuvring coffins and deceased persons
- Back injuries from handling heavy or bariatric cases
- Strains from working in confined spaces such as bedrooms, stairwells, or vehicles
- Injuries from poor posture when transferring from stretchers, trolleys, or beds
- Crush injuries to hands or feet during coffin placement or vehicle loading
- Team handling failures due to poor coordination or uneven load distribution
- Handling on uneven ground in cemeteries or outdoor burial sites
- Slips or trips while carrying loads, especially in wet weather
- Fatigue during prolonged or emotionally demanding tasks
- Poor access routes in private homes increasing handling difficulty
Training
- Manual handling training specific to coffin and deceased handling
- Training on use of stretchers, trolleys, hoists, ramps, and lifting aids
- Team handling training with clear communication and coordinated movements
- Training on handling in confined spaces and on stairs
- Awareness training on managing fatigue and emotional stress during handling tasks
- Supervisor training to assess dynamic risks at collection locations
Maintenance
- Regular inspection and maintenance of stretchers, wheeled biers, trolleys, and hoists
- Checks on vehicle lifts, ramps, rollers, and securing systems
- Ensure wheels, brakes, and frames of handling equipment are in good condition
- Maintain clear, well-lit routes in funeral homes and crematoria
- Maintenance of external paths in cemeteries and burial grounds
- Replace worn PPE such as gloves and safety footwear
- Review risk assessments following incidents or changes in equipment
SSOW & Supervision
- Avoid manual lifting where reasonably practicable by using mechanical aids
- Assess each removal or transfer using TILEO principles before starting
- Plan routes in advance, considering stairs, tight spaces, and obstacles
- Use team lifts for coffins and bariatric cases with clear leadership and communication
- Use appropriate equipment for stairs and confined spaces
- Position vehicles to minimise carrying distance wherever possible
- Ensure appropriate staffing levels for the weight and size of the load
- Pause work if conditions are unsafe (poor lighting, slippery ground)
- Supervisors monitor technique and ensure staff are fit for the task
Checklist
- Has hazardous manual handling been avoided where reasonably practicable through use of trolleys, hoists, or other aids?
MHOR Reg 4(1)(a); HSWA s2 - Where manual handling cannot be avoided, has a suitable and sufficient risk assessment been completed for coffin and deceased handling?
MHOR Reg 4(1)(b)(i); MHSWR Reg 3 - Does the assessment consider confined spaces, stairs, uneven ground, and emotional stress?
MHOR Reg 4; Schedule 1 - Are mechanical aids such as stretchers, wheeled biers, hoists, and ramps provided and used?
MHOR Reg 4(1)(b)(ii) - Are sufficient trained staff available for team handling tasks?
MHOR Reg 4; HSWA s2 - Are routes assessed and cleared before moving a coffin or deceased person?
MHOR Reg 4 - Is information available about coffin weight and any additional load factors (e.g. bariatric cases)?
MHOR Reg 4(1)(b)(iii) - Is the working environment suitable (lighting, space, floor condition, weather)?
MHOR Reg 4; Schedule 1 - Have individual capabilities been considered (fitness, pregnancy, existing injuries)?
MHOR Reg 4(3) - Have staff received task-specific training in funeral handling techniques and equipment use?
MHOR Reg 4; HSWA s2 - Are handling aids inspected and maintained in safe working order?
PUWER; MHOR Reg 4 - Are manual handling incidents, near misses, and ill-health reports reviewed?
MHOR Reg 4; MHSWR Reg 5 - Are risk assessments reviewed following incidents or changes in equipment or procedures?
MHOR Reg 4(2)
Legal References
- Manual Handling Operations Regulations 1992 (as amended) – Reg 4 (avoid, assess, reduce), Reg 5 (information/training)
- Health and Safety at Work etc. Act 1974 – s2, s3
- Management of Health and Safety at Work Regulations 1999 – Reg 3 (risk assessment), Reg 13 (capabilities)
- Provision and Use of Work Equipment Regulations 1998 (PUWER)
- HSE Guidance HSG60 – Manual Handling
- INDG143 – Manual Handling at Work (HSE guide)
▶ Risks
- Crush or trapping injuries from coffin lifts, trolleys, hydraulic biers and vehicle tail lifts
- Contact with moving parts on coffin lowering devices, conveyors or cremator charging systems
- Struck-by injuries from unstable loads or shifting coffins during handling or transport
- Mechanical failure due to poor maintenance of lifting aids, mortuary tables or transfer equipment
- Unexpected start-up of powered equipment during cleaning or maintenance
- Electrical hazards from powered mortuary equipment, refrigeration units, and portable tools
- Burns from hot surfaces associated with cremators or associated plant
- Pinch-point injuries from adjustable-height tables, lifting platforms and trolley mechanisms
- Poor workstation design causing ergonomic strain during preparation or transfer tasks
- Inadequate guarding on mechanical handling or crematorium equipment
- Use of unsuitable or overloaded lifting equipment for coffin or bariatric transfers
- Risks to colleagues or visitors from poorly positioned equipment or obstructed routes
▶ Training
- Operator training on safe use of coffin lifts, hydraulic trolleys, and transfer equipment
- Training on safe use of tail lifts and vehicle loading equipment
- Training on pre-use checks and defect reporting
- Task-specific training for cremator charging systems and associated plant (where applicable)
- Training on safe cleaning and isolation before maintenance
- Supervisor training to monitor compliance and prevent bypassing of safety devices
- Induction training covering emergency stops, isolation points and safe traffic routes
▶ Maintenance
- Pre-use checks appropriate to the equipment (wheels, brakes, hydraulics, guards, cables)
- Regular inspection at risk-based intervals (PUWER Reg 6)
- Preventive maintenance in line with manufacturer guidance for lifts, trolleys and plant
- Portable appliance testing (PAT) where appropriate
- Immediate isolation and removal from service of defective equipment
- Guarding, interlocks and emergency stop devices tested and maintained
- Inspection and maintenance of powered loading systems and lifting aids
- Records kept of inspections and maintenance where required
▶ SSOW & Supervision
- Ensure equipment is suitable for the load, environment and dignity requirements of the task
- Position equipment safely with clear, level routes and adequate space
- Maintain guarding and safety devices — no removal or bypass
- Use safe start/stop procedures and isolate equipment before cleaning or maintenance
- Keep bystanders and visitors away from work areas and mechanical handling operations
- Good housekeeping around equipment (no trailing cables, clear floors, stable surfaces)
- Use PPE where required (e.g. gloves, safety footwear during transfers)
- Supervisors enforce safe behaviour and correct use of equipment
▶ Checklist
- Is the work equipment suitable for the task, load and environment in which it operates?
PUWER Reg 4; HSWA s2 - Has a suitable and sufficient risk assessment been carried out for risks from lifting and transfer equipment?
MHSWR Reg 3; PUWER Reg 4 - Is equipment used only under conditions for which it is suitable?
PUWER Reg 4(3) - Is equipment maintained in efficient working order and good repair?
PUWER Reg 5 - Where deterioration could lead to danger, is equipment inspected at appropriate intervals?
PUWER Reg 6 - Are inspection and maintenance records available where required?
PUWER Reg 6(3) - Where equipment involves specific risks (e.g. hydraulic lifts, cremator systems), is its use restricted to trained persons?
PUWER Reg 7 - Are users and supervisors provided with adequate information, instruction and training?
PUWER Regs 8 & 9; HSWA s2 - Are dangerous parts of machinery adequately guarded or otherwise protected?
PUWER Reg 11 - Are controls clearly identifiable and designed to prevent unintended operation?
PUWER Regs 14–17 - Are effective stop and emergency stop controls provided and functioning where appropriate?
PUWER Regs 15 & 16 - Can equipment be safely isolated from energy sources for maintenance and cleaning?
PUWER Reg 19 - Is equipment stable and secured where necessary?
PUWER Reg 20 - Is suitable lighting provided for safe use and maintenance of equipment?
PUWER Reg 21 - Are appropriate markings and warnings provided and understood?
PUWER Regs 23–24 - Are employees using equipment in accordance with systems of work, training and instructions provided?
HSWA s7; PUWER Reg 9
▶ Legal References
- PUWER 1998 – Regs 4–24 (suitability, maintenance, inspection, guarding, controls, isolation)
- HSWA 1974 – s2, s3
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- ACoP L22 – Safe Use of Work Equipment
- Manufacturer guidance and relevant BS/EN standards for lifting and transfer equipment
to complete
Risks
- Wet floors at entrances from rainwater, umbrellas, and wet footwear (particularly during services)
- Spills from refreshments (tea/coffee/water) in reception areas, arrangement rooms, and lounges
- Cleaning and polishing activities creating temporary slippery surfaces
- Wax drips and polish residue on chapel floors and ceremonial areas
- Trips from floral tributes, stands, condolence books, donation boxes, and signage placed in walkways
- Trailing cables from AV, microphones, livestream equipment, lighting, and portable heaters/fans
- Crowding and reduced awareness due to distress, low attention, or mobility limitations
- Loose or poorly secured mats and rugs, especially at entrances and chapels of rest
- Steps, thresholds, ramps, and uneven surfaces within older buildings
- Low lighting in chapels of rest, viewing rooms, and during candlelit/low-light services
- Outdoor hazards in cemeteries and crematoria grounds: uneven paths, kerbs, potholes, loose gravel, wet leaves, mud, algae, and ice
- Falls during coffin handling, vehicle loading/unloading, or while carrying/positioning equipment
- Trips in back-of-house areas (workshops, stores, embalming/prep rooms) from equipment, trolleys, and packaging
Training
- Staff training on prompt spill response, safe cleaning methods, and temporary access control
- Training on safe layout management for services (keeping routes to seating, exits, and toilets clear)
- Training on cable management for AV/livestream setups and safe use of cable covers
- Manual handling training for coffins, trolleys, and ceremonial equipment (including team lifts)
- Training on assisting vulnerable visitors (mobility issues, visual impairment, distress)
- Induction training covering internal and external slip/trip hotspots (entrances, chapels, grounds)
- Supervisor training to monitor housekeeping standards and pre-service safety checks
Maintenance
- Regular inspections of floors, mats, thresholds, steps, handrails, and lighting
- Prompt repair of damaged flooring, loose tiles, worn stair nosings, and uneven surfaces
- Maintain effective entrance matting (length, condition, and cleaning to prevent saturation)
- Routine maintenance of external paths, kerbs, ramps, and car parks (including pothole repairs)
- Seasonal controls for outdoor areas: leaf clearance, algae/moss treatment, winter gritting plan
- Maintain lighting levels in chapels, viewing rooms, corridors, toilets, and external routes
- Inspection/maintenance of trolleys, bier rollers, ramps, and lifting aids where used
SSOW & Supervision
- Keep primary routes clear at all times (entrances, reception, chapels, toilets, exits)
- Position floral displays, condolence books, and stands so they do not narrow walkways
- Manage spill risks during refreshments: prompt cleanup and isolate until dry
- Use appropriate signage during cleaning and remove once surfaces are fully dry
- Control cables for AV/livestream equipment using routed edges, covers, or overhead solutions
- Use slip-resistant footwear for staff where floors may become wet or polished
- Before services, complete a walk-through check of seating routes, lighting, steps, and exits
- During services, assign staff to discreetly monitor entrances for water ingress and congestion
- Assist visitors with reduced mobility: offer arm support, guidance on steps/ramps, and accessible routes
- For cemeteries/grounds, direct visitors to maintained paths and restrict access to unsafe areas
- Use safe systems for coffin handling: clear routes, team handling, controlled pace, and suitable equipment
- Supervisors monitor housekeeping, layout discipline, and external route conditions (ice/leaves)
Checklist
- Has a suitable and sufficient risk assessment been carried out for slip, trip and fall hazards affecting staff and members of the public, including vulnerable visitors?
MHSWR Reg 3; HSWA ss2–4; INDG225 - Does the assessment consider service-specific factors such as crowding, low lighting, distress, and reduced attention?
MHSWR Reg 3 - Are floors and traffic routes suitable, well maintained, and not made unnecessarily slippery by polishing/cleaning practices?
Workplace Reg 12; INDG225 - Are entrance controls effective (matting, umbrellas/wet-weather arrangements, monitoring during busy periods)?
Workplace Reg 12; INDG225 - Are walkways, exits, and toilet routes kept free from obstructions including floral tributes, stands, signage, and furniture?
Workplace Reg 12(3); HSWA s2 - Are arrangements in place for prompt cleanup of spillages from refreshments and for isolating areas until safe?
Workplace Reg 12; INDG225 - Are cables from AV/livestreaming equipment routed safely and controlled using covers or alternative routing?
Workplace Reg 12(3); HSWA s2 - Is lighting suitable and sufficient in chapels of rest, viewing rooms, corridors, and external approaches?
Workplace Reg 8 - Are steps, ramps, and changes in level clearly visible, in good condition, and provided with suitable handrails where required?
Workplace Regs 12, 13 - Are external paths, car parks, and cemetery routes maintained to prevent slips/trips (potholes, uneven ground, loose gravel)?
Workplace Reg 12; HSWA s3 - Are seasonal hazards managed (wet leaves, algae, ice) with a documented inspection and gritting/clearance plan?
MHSWR Reg 5; Workplace Reg 12 - Is suitable slip-resistant footwear provided/required for staff involved in cleaning, grounds work, or wet-weather management?
PPE Regs 1992; HSWA s2 - Are safe systems in place for coffin handling and equipment movement, including route checks, controlled pace, and use of trolleys/ramps?
HSWA s2; MHSWR Reg 5 - Are slip, trip and fall incidents and near misses recorded, reviewed, and used to improve layout, maintenance, and controls?
MHSWR Reg 5; HSWA s2 - Are control measures reviewed following incidents, changes to premises/layout, or seasonal changes affecting external routes?
MHSWR Reg 3(3); INDG225
Legal References
- Workplace (Health, Safety & Welfare) Regulations 1992 – Reg 12 (floors and traffic routes), Reg 17 (traffic routes), Reg 8 (lighting)
- Health and Safety at Work etc. Act 1974 – s2, s3 (public protection particularly relevant on visitor routes and grounds)
- Management of Health and Safety at Work Regulations 1999 – Reg 3 (risk assessment), Reg 5 (arrangements)
- Personal Protective Equipment at Work Regulations 1992 (as amended) – footwear and PPE where required
- HSE Guidance: INDG225 (Slips & Trips), HSG155 (Slips & Trips in the Workplace)
to complete