Leisure, Entertainment & Cultural Venues
▶ Risks
- Electric shock from damaged or unsuitable equipment
- Fire from overloaded circuits, faulty wiring, or poor extension lead management
- Contact with live parts (poor guarding, faulty plugs, exposed wiring)
- Use of equipment in wet environments (increased shock risk)
- Trip hazards from trailing cables
- Unsafe use of multi-adaptors or daisy chains
- Damaged lighting circuits, cracked sockets, loose faceplates
- Portable appliances not maintained
- Faulty fixed wiring (old systems, missing RCDs, poorly protected circuits)
- Inadequate control of contractors working on live systems
▶ Training
- User awareness training (basic electrical hazards, visual checks)
- Training to identify damaged cables, plugs, and equipment
- Staff trained to report and isolate faulty items
- Competent electrician required for repairs and fixed wiring work
- Awareness that water + electrics increase risk
- Managers and supervisors trained to monitor cable use and overload risks
▶ Maintenance
- User visual checks before use
- PAT testing at risk-based intervals (no legal fixed frequency)
- Removal of damaged equipment from service immediately
- Fixed wiring inspection/report (EICR) by competent electrician — frequency based on risk (commonly 5 years for commercial premises)
- Routine checks of sockets, plugs, extension reels, and multi-adapters
- Ensure RCD protection where required
- Maintenance of emergency lighting and fire alarm circuits
▶ SSOW & Supervision
- Remove faulty equipment from service immediately (tag and isolate)
- No trailing or damaged cables — maintain tidy cable routing
- Do not overload sockets; avoid daisy-chaining
- Use correct equipment for damp or wet areas (IP-rated equipment)
- Ensure only competent electricians work on installations
- Provide RCD protection where reasonably practicable
- Clear procedure for reporting and dealing with electrical faults
- Supervisors monitor cable use, housekeeping, and condition of appliances
▶ Checklist
- Signs of unsafe electrical installation or equipment (e.g. exposed wires, burn marks, overheating, damaged sockets, reports of shocks)
EAWR Reg 4(1); Reg 4(2); Reg 6; HSG85 paras 7–10, 12 - Electrical equipment or installations appear damaged, poorly maintained or unsafe
EAWR Reg 4(2); Reg 6; Reg 16; HSG85 paras 8, 10, 12 - Exposed live parts or missing covers on sockets, switches, distribution boards or consumer units
EAWR Reg 4(1); Reg 14; HSG85 paras 7, 10, 14 - Electrical systems used in conditions likely to cause danger (e.g. damp environments, water ingress, unsuitable equipment for location)
EAWR Reg 4(1); Reg 4(3); HSG85 paras 12–13 - Distribution boards, fuse boxes or consumer units secure, protected and not obstructed
EAWR Reg 4(1); Reg 15; HSG85 paras 10, 15 - Means of electrical isolation provided and clearly identifiable
EAWR Reg 12; Reg 15; HSG85 paras 15, 47–49 - Electrical isolation points accessible and not locked shut or obstructed
EAWR Reg 12; Reg 15; HSG85 paras 49–52 - Portable electrical equipment appears in good condition (no damaged plugs, cables, joints or casings)
EAWR Reg 4(2); Reg 6; HSG85 paras 8, 12 - No evidence of unsafe electrical practices (e.g. trailing leads, overloaded sockets, multiple adapters, improvised wiring)
EAWR Reg 4(1); Reg 4(3); Reg 16; HSG85 paras 7, 14, 26 - Fixed electrical installations appear to be maintained so as to prevent danger
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9 - Dutyholder able to provide evidence of periodic inspection and testing of fixed electrical installations (e.g. EICR)
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9, 18
Note: HSE guidance recognises periodic inspection and testing (commonly every 5 years in many non-domestic premises, or more frequently where risk is higher) as a means of demonstrating compliance. - Evidence of inspection, testing or competent electrician involvement available where appropriate
EAWR Reg 4(2); Reg 16; HSG85 paras 18, 40–41 - Electrical work appears to be carried out by competent persons (not unqualified staff or DIY)
EAWR Reg 16; HSG85 paras 18, 40–41 - No evidence of live electrical work being carried out where it could reasonably be avoided
EAWR Reg 14; HSG85 paras 23–24
▶ Legal References
- HSWA 1974 – s2, s3 (duty to ensure electrical safety)
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- Electricity at Work Regulations 1989 – Regs 4–16 (core electrical safety duties)
- PUWER 1998 – Reg 4 (suitability), Reg 5 (maintenance), Reg 6 (inspection), Reg 9 (training)
- Workplace (Health, Safety & Welfare) Regs 1992 – Reg 12 (condition of floors/lighting)
- BS 7671 (IET Wiring Regulations) – benchmark for safe fixed installations
- HSE HSG107 & INDG236 – electrical equipment guidance (PAT, user checks)
to complete
▶ Risks
- Contact with moving parts in stage machinery, winches, track systems, curtains, lifts and ride/attraction equipment
- Crush or trapping injuries from retractable seating, staging, scenery trucks or lifting platforms
- Struck-by injuries from falling props, lighting fixtures, scenery or display items
- Mechanical failure due to poor maintenance of stage equipment, lifts or attraction machinery
- Unexpected start-up of powered equipment during maintenance, rehearsals or scene changes
- Electrical hazards from AV systems, lighting rigs, projectors, arcade machines and portable equipment
- Noise exposure during setup, rehearsals or maintenance of amplified sound systems
- Burns from hot lighting units, projectors, catering equipment or special effects devices
- Poor workstation design causing ergonomic strain (repetitive ticket desk tasks, awkward backstage handling)
- Inadequate guarding or defeated safety interlocks on machinery or attraction equipment
- Use of unsuitable or improvised equipment for staging, rigging or maintenance tasks
- Risks to staff, performers and visitors from poor layout, trailing cables, or unprotected equipment
▶ Training
- Operator training on safe use of stage machinery, lifting platforms and powered scenery systems
- Training for technicians on safe use of lighting, AV and rigging equipment
- Training on pre-use checks and defect reporting
- Task-specific training for cleaning machines, compactors or attraction machinery
- Training in safe isolation before maintenance, adjustments or scene changes
- Supervisor and duty manager training to monitor compliance and prevent bypassing of guards or safety systems
- Induction training covering emergency stops, exclusion zones and safe equipment practices
▶ Maintenance
- Pre-use checks appropriate to the equipment (guards, cables, fixings, interlocks)
- Regular inspection at risk-based intervals (PUWER Reg 6)
- Preventive maintenance in line with manufacturer and industry guidance
- Portable appliance testing (PAT) where appropriate
- Immediate isolation and removal from service of defective equipment
- Guarding, interlocks, brakes and safety devices tested and maintained
- Functional testing of emergency stops on stage, ride or attraction equipment
- Inspection of lifting or moving stage elements and tracking systems
- Records kept of inspections and maintenance where required
▶ SSOW & Supervision
- Ensure equipment is suitable for the performance, display or attraction and the environment in which it operates
- Position equipment safely and maintain clear routes for staff and the public
- Maintain guarding and interlocks — zero tolerance for removal or bypass
- Use safe start/stop procedures and isolate equipment before cleaning, maintenance or set changes
- Keep unauthorised persons away from backstage, plant rooms and equipment zones
- Good housekeeping around equipment (secure cables, tidy backstage areas, stable props)
- Use PPE where required (e.g. gloves for handling scenery, hearing protection during setup)
- Supervisors enforce safe behaviour and correct use of technical equipment
▶ Checklist
- Is the work equipment suitable for the task, environment and level of public interaction?
PUWER Reg 4; HSWA s2 - Has a suitable and sufficient risk assessment been carried out for risks from stage, AV and attraction equipment?
MHSWR Reg 3; PUWER Reg 4 - Is equipment used only under conditions for which it is suitable?
PUWER Reg 4(3) - Is equipment maintained in efficient working order and good repair?
PUWER Reg 5 - Where deterioration could lead to danger, is equipment inspected at appropriate intervals?
PUWER Reg 6 - Are inspection and maintenance records available where required?
PUWER Reg 6(3) - Where equipment involves specific risks (e.g. stage lifts, ride systems), is its use restricted to trained persons?
PUWER Reg 7 - Are users and supervisors provided with adequate information, instruction and training?
PUWER Regs 8 & 9; HSWA s2 - Are dangerous parts of machinery adequately guarded or otherwise protected?
PUWER Reg 11 - Are controls clearly identifiable and designed to prevent unintended operation?
PUWER Regs 14–17 - Are effective stop and emergency stop controls provided and functioning where appropriate?
PUWER Regs 15 & 16 - Can equipment be safely isolated from energy sources for maintenance and adjustments?
PUWER Reg 19 - Is equipment stable and secured where necessary?
PUWER Reg 20 - Is suitable lighting provided for safe use and maintenance of equipment?
PUWER Reg 21 - Are appropriate markings and warnings provided and understood?
PUWER Regs 23–24 - Are employees using equipment in accordance with systems of work, training and instructions provided?
HSWA s7; PUWER Reg 9
▶ Legal References
- PUWER 1998 – Regs 4–24 (suitability, maintenance, inspection, guarding, controls, isolation)
- HSWA 1974 – s2, s3
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- ACoP L22 – Safe Use of Work Equipment
- Relevant industry guidance and manufacturer instructions for stage, AV and attraction equipment
Risks
- Exposure to cleaning chemicals used in public areas, toilets, and catering spaces
- Respiratory irritation from theatrical smoke, haze, and fog effects
- Skin contact with paints, adhesives, and solvents used for set construction and maintenance
- Exposure to aerosols and sprays during maintenance or pest control
- Dermatitis from frequent wet work and cleaning tasks
- Sensitisation from glues, resins, and specialist prop-making materials
- Chemical burns from descalers, disinfectants, or pool chemicals (where leisure pools/spas exist)
- Carbon monoxide or exhaust fume exposure from generators or equipment used indoors
- Improper mixing of cleaning agents creating toxic gases
- Fire risk from flammable liquids, paints, and pyrotechnic materials
Training
- COSHH awareness training relevant to venue operations and maintenance
- Task-specific training for use of stage effects (smoke, haze, fog fluids)
- Training on safe use of paints, solvents, adhesives, and cleaning agents
- Training on reading Safety Data Sheets (SDS) and hazard labels
- Correct PPE use including gloves, eye protection, and RPE where required
- First-aid training for chemical splashes, inhalation exposure, and burns
- Supervisor training to ensure safe storage and use during events and maintenance
Maintenance
- Maintain up-to-date COSHH assessments and Safety Data Sheets for all substances
- Routine checks of general ventilation and local extraction in workshops or backstage areas
- LEV systems thoroughly examined and tested every 14 months where fitted
- Safe storage of chemicals in labelled containers with segregation of incompatibles
- Replace damaged PPE and maintain RPE filters where used
- Check expiry dates on chemicals such as pool treatment products or stage fluids
- Maintenance of plant rooms and fuel storage areas to prevent leaks and vapour build-up
SSOW & Supervision
- Substitute hazardous substances with safer alternatives where practicable
- Use engineering controls such as ventilation and extraction when using vapour-producing substances
- Follow manufacturer instructions for dilution, mixing, and use of chemicals
- Keep containers closed when not in use and store securely
- Prevent mixing incompatible substances (e.g. chlorine and acids)
- Use suitable PPE (gloves, goggles, aprons, RPE) based on risk assessment
- Provide washing and welfare facilities to reduce skin exposure
- Ensure safe handling and storage of fuels or pyrotechnic materials by competent persons
- Spill response procedures and kits available in relevant areas
- Supervisors monitor compliance with COSHH controls during events and maintenance work
Checklist
- Have all hazardous substances (cleaners, paints, stage fluids, fuels) been identified?
COSHH Reg 6 - Are suitable and sufficient COSHH assessments available and up to date?
COSHH Reg 6(1), 6(3) - Are hazardous substances stored safely and labelled correctly?
COSHH Reg 7; Schedule 7 - Is exposure to vapours, fumes, mists, or skin contact prevented or adequately controlled?
COSHH Reg 7 - Are control measures appropriate (ventilation, extraction, PPE)?
COSHH Reg 7(3)–(4) - Are control measures used correctly and not bypassed?
COSHH Reg 7(7) - Is LEV or other engineering control maintained and tested where required?
COSHH Reg 9 - Are staff trained in safe handling and emergency procedures?
COSHH Reg 12 - Are Safety Data Sheets accessible to staff?
COSHH Reg 6(2)(b) - Are arrangements in place to deal with spills, leaks, or accidental exposure?
COSHH Reg 13 - Are hazardous wastes stored and disposed of safely?
COSHH Reg 7; environmental legislation - Are there no obvious signs of uncontrolled exposure (strong odours, visible vapours)?
COSHH Reg 7
Legal References
- Control of Substances Hazardous to Health Regulations 2002 – Regs 6–13
- Health and Safety at Work etc. Act 1974 – s2, s3
- Management of Health and Safety at Work Regulations 1999 – Reg 3 (risk assessment), Reg 10 (training)
- HSG193 (COSHH Essentials), HSG258 (LEV), INDG136 (COSHH guide)
- Safety Data Sheet requirements under REACH & CLP Regulations
Risks
- Spillages of drinks and food in auditoriums, seating areas, bars, and concourses
- Low lighting in performance spaces, cinemas, and during events
- Trips on steps between seating rows, tiered floors, and changes in level
- Loose carpets, worn stair nosings, and uneven flooring in high-traffic areas
- Trailing cables from AV, lighting, staging, DJ equipment, and temporary installations
- Obstructed walkways due to queues, temporary barriers, merchandise stands, or crowding
- Wet floors in entrance areas from rain, snow, or wet clothing
- Slippery floors in bar areas from drink spills and glass breakages
- Props, costumes, scenery, and stage equipment creating backstage trip hazards
- Outdoor event hazards such as mud, uneven ground, temporary flooring, and cable runs
- Visitors distracted by screens, performances, or exhibits and not watching where they walk
- Increased risks during changeovers, set builds, and post-event clear-down
Training
- Staff training on rapid spill response and safe cleanup during events
- Training for bar and catering staff on managing drink spills and broken glass safely
- Front-of-house staff training to monitor aisles, steps, and audience areas during events
- Backstage and technical crew training on cable management and housekeeping
- Event setup crews trained to maintain safe access routes during builds and breakdowns
- Induction training covering venue-specific hazards such as tiered seating and low lighting
- Supervisor training to coordinate safety checks before, during, and after events
Maintenance
- Regular inspection of floors, steps, stair nosings, handrails, and seating access routes
- Repair or replacement of worn carpets, loose flooring, and damaged anti-slip surfaces
- Maintenance of entrance matting and lobby flooring during wet weather
- Routine checks of lighting systems, including step and aisle lighting
- Inspection and maintenance of temporary flooring and staging
- Regular inspection of external areas, queuing routes, and car parks
- Seasonal controls for outdoor hazards such as leaves, moss, and ice
SSOW & Supervision
- Keep aisles, gangways, and exits clear at all times, including during performances
- Clean spills promptly; isolate and dry areas before reopening to the public
- Use signage and staff presence to warn of temporary hazards
- Ensure step edges are clearly visible with contrasting nosings or lighting
- Provide and maintain effective aisle and low-level lighting in darkened venues
- Route cables away from public walkways or protect them with cable covers
- Manage queues to prevent overcrowding and blocked walkways
- Ensure temporary event layouts maintain safe routes to exits and facilities
- Backstage areas kept tidy with props, cases, and equipment stored safely
- Carry out pre-event and interval checks of public areas and access routes
- Provide suitable slip-resistant footwear for staff working in bars, kitchens, or wet areas
- Supervisors monitor floor conditions throughout events, especially in bars and entrances
Checklist
- Has a suitable and sufficient risk assessment been completed for slip, trip and fall hazards affecting staff, performers, and the public?
MHSWR Reg 3; HSWA ss2–4; INDG225 - Does the assessment consider low lighting, crowd behaviour, and distracted visitors?
MHSWR Reg 3 - Are floors, steps, and seating access routes suitable, well maintained, and slip resistant where needed?
Workplace Reg 12; INDG225 - Are aisles, gangways, and exits kept free from obstructions including bags, equipment, and temporary displays?
Workplace Reg 12(3); HSWA s2 - Are effective arrangements in place for prompt cleanup of drink and food spills?
Workplace Reg 12; INDG225 - Are step edges and changes in level clearly visible, especially in low light?
Workplace Regs 12, 13 - Are cables from AV, lighting, and staging safely routed or protected?
Workplace Reg 12(3); HSWA s2 - Is lighting suitable and sufficient for safe movement in all accessible areas?
Workplace Reg 8 - Are external queuing areas, paths, and car parks maintained to prevent slips and trips?
Workplace Reg 12; HSWA s3 - Are seasonal hazards such as wet leaves, mud, and ice managed effectively?
MHSWR Reg 5; Workplace Reg 12 - Are staff provided with suitable footwear where floors are likely to be contaminated?
PPE Regs 1992; HSWA s2 - Are incidents and near misses involving slips, trips, and falls recorded and reviewed?
MHSWR Reg 5; HSWA s2 - Are control measures reviewed after incidents, layout changes, or different event types?
MHSWR Reg 3(3); INDG225
Legal References
- Workplace (Health, Safety & Welfare) Regulations 1992 – Reg 12 (floors and traffic routes), Reg 17 (traffic routes), Reg 8 (lighting)
- Health and Safety at Work etc. Act 1974 – s2, s3
- Management of Health and Safety at Work Regulations 1999 – Reg 3 (risk assessment), Reg 5 (arrangements)
- Personal Protective Equipment at Work Regulations 1992 (as amended)
- HSE Guidance: INDG225 (Slips & Trips), HSG155 (Slips & Trips in the Workplace)
to complete