Offices & Administrative Premises
▶ Risks
- Electric shock from damaged or unsuitable equipment
- Fire from overloaded circuits, faulty wiring, or poor extension lead management
- Contact with live parts (poor guarding, faulty plugs, exposed wiring)
- Use of equipment in wet environments (increased shock risk)
- Trip hazards from trailing cables
- Unsafe use of multi-adaptors or daisy chains
- Damaged lighting circuits, cracked sockets, loose faceplates
- Portable appliances not maintained
- Faulty fixed wiring (old systems, missing RCDs, poorly protected circuits)
- Inadequate control of contractors working on live systems
▶ Training
- User awareness training (basic electrical hazards, visual checks)
- Training to identify damaged cables, plugs, and equipment
- Staff trained to report and isolate faulty items
- Competent electrician required for repairs and fixed wiring work
- Awareness that water + electrics increase risk
- Managers and supervisors trained to monitor cable use and overload risks
▶ Maintenance
- User visual checks before use
- PAT testing at risk-based intervals (no legal fixed frequency)
- Removal of damaged equipment from service immediately
- Fixed wiring inspection/report (EICR) by competent electrician — frequency based on risk (commonly 5 years for commercial premises)
- Routine checks of sockets, plugs, extension reels, and multi-adapters
- Ensure RCD protection where required
- Maintenance of emergency lighting and fire alarm circuits
▶ SSOW & Supervision
- Remove faulty equipment from service immediately (tag and isolate)
- No trailing or damaged cables — maintain tidy cable routing
- Do not overload sockets; avoid daisy-chaining
- Use correct equipment for damp or wet areas (IP-rated equipment)
- Ensure only competent electricians work on installations
- Provide RCD protection where reasonably practicable
- Clear procedure for reporting and dealing with electrical faults
- Supervisors monitor cable use, housekeeping, and condition of appliances
▶ Checklist
- Signs of unsafe electrical installation or equipment (e.g. exposed wires, burn marks, overheating, damaged sockets, reports of shocks)
EAWR Reg 4(1); Reg 4(2); Reg 6; HSG85 paras 7–10, 12 - Electrical equipment or installations appear damaged, poorly maintained or unsafe
EAWR Reg 4(2); Reg 6; Reg 16; HSG85 paras 8, 10, 12 - Exposed live parts or missing covers on sockets, switches, distribution boards or consumer units
EAWR Reg 4(1); Reg 14; HSG85 paras 7, 10, 14 - Electrical systems used in conditions likely to cause danger (e.g. damp environments, water ingress, unsuitable equipment for location)
EAWR Reg 4(1); Reg 4(3); HSG85 paras 12–13 - Distribution boards, fuse boxes or consumer units secure, protected and not obstructed
EAWR Reg 4(1); Reg 15; HSG85 paras 10, 15 - Means of electrical isolation provided and clearly identifiable
EAWR Reg 12; Reg 15; HSG85 paras 15, 47–49 - Electrical isolation points accessible and not locked shut or obstructed
EAWR Reg 12; Reg 15; HSG85 paras 49–52 - Portable electrical equipment appears in good condition (no damaged plugs, cables, joints or casings)
EAWR Reg 4(2); Reg 6; HSG85 paras 8, 12 - No evidence of unsafe electrical practices (e.g. trailing leads, overloaded sockets, multiple adapters, improvised wiring)
EAWR Reg 4(1); Reg 4(3); Reg 16; HSG85 paras 7, 14, 26 - Fixed electrical installations appear to be maintained so as to prevent danger
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9 - Dutyholder able to provide evidence of periodic inspection and testing of fixed electrical installations (e.g. EICR)
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9, 18
Note: HSE guidance recognises periodic inspection and testing (commonly every 5 years in many non-domestic premises, or more frequently where risk is higher) as a means of demonstrating compliance. - Evidence of inspection, testing or competent electrician involvement available where appropriate
EAWR Reg 4(2); Reg 16; HSG85 paras 18, 40–41 - Electrical work appears to be carried out by competent persons (not unqualified staff or DIY)
EAWR Reg 16; HSG85 paras 18, 40–41 - No evidence of live electrical work being carried out where it could reasonably be avoided
EAWR Reg 14; HSG85 paras 23–24
▶ Legal References
- HSWA 1974 – s2, s3 (duty to ensure electrical safety)
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- Electricity at Work Regulations 1989 – Regs 4–16 (core electrical safety duties)
- PUWER 1998 – Reg 4 (suitability), Reg 5 (maintenance), Reg 6 (inspection), Reg 9 (training)
- Workplace (Health, Safety & Welfare) Regs 1992 – Reg 12 (condition of floors/lighting)
- BS 7671 (IET Wiring Regulations) – benchmark for safe fixed installations
- HSE HSG107 & INDG236 – electrical equipment guidance (PAT, user checks)
▶ Risks
- Slips due to wet floors, spills, cleaning, or contamination (oil, dust, food residue)
- Trips from trailing cables, poor housekeeping, or uneven flooring
- Falls caused by damaged or poorly maintained floor surfaces
- Sudden changes in floor level (steps, thresholds, ramps)
- Poor lighting increasing slip and trip risk
- Weather-related hazards (rainwater at entrances, ice in yards)
- Obstructed walkways or stock stored in aisles
- Inadequate footwear for the environment
- Injuries to members of the public in shops, gyms, and leisure facilities
▶ Training
- Staff training on spill response and immediate reporting
- Awareness training on good housekeeping and correct storage
- Training on safe cleaning methods and signage use
- Induction training covering walkways, PPE, and slip risks
- Supervisor training to identify and enforce housekeeping standards
▶ Maintenance
- Regular inspections of floors, walkways, stairs, and lighting
- Prompt repair of damaged flooring, mats, tiles, and potholes
- Maintenance of entrance matting and external surfaces
- Review and upkeep of drainage, gutters, and anti-slip coatings
- Maintenance of lighting (replace failed lamps promptly)
- Regular checks on footwear suitability where provided
▶ SSOW & Supervision
- Keep walkways clear and well lit; maintain good housekeeping
- Immediate cleanup of spills using proper methods (not spreading contamination)
- Use appropriate signage during cleaning and remove when the floor is dry
- Control cable routing and avoid trailing leads in walkways
- Use suitable entrance matting and manage water ingress during wet weather
- Store stock safely to prevent obstructions
- Use slip-resistant footwear where risk justifies it
- Adjust pace of work to conditions (e.g. kitchens, bars, gyms)
- Supervisors monitor compliance with housekeeping and spill procedures
▶ Checklist
- Has a suitable and sufficient risk assessment been carried out for slip, trip and fall hazards?
MHSWR Reg 3; HSWA ss2–4; INDG225 - Does the risk assessment identify foreseeable slip, trip and fall hazards, including floor contamination, uneven surfaces, changes in level and obstructions?
MHSWR Reg 3; INDG225 - Are floors and traffic routes suitable for the purpose, in good condition and free from holes, unevenness or slippery conditions?
Workplace Reg 12; ACOP & INDG225 - Are floors kept free from obstructions, trailing cables, waste and materials that could cause trips?
Workplace Reg 12(3); HSWA s2 - Are spillages and contamination (water, oil, food, dust) prevented so far as reasonably practicable?
HSWA s2; INDG225 - Where contamination cannot be avoided, are effective control measures in place (e.g. mats, drainage, task design, segregation)?
MHSWR Reg 4; INDG225 - Are effective arrangements in place for routine cleaning and for dealing promptly with spillages?
Workplace Reg 12; INDG225 - Are cleaning methods suitable for the type of flooring and do they avoid creating additional slip risks?
INDG225 - Is flooring suitable for the environment (e.g. slip resistance where floors are likely to become wet)?
Workplace Reg 12(2); INDG225 - Is lighting suitable and sufficient to allow people to see hazards such as steps, slopes, changes in level and obstructions?
Workplace Reg 8 - Are steps, stairs, ramps and changes in level clearly visible, in good condition and provided with suitable handrails where required?
Workplace Regs 12, 13 - Are pedestrian routes appropriately designed, maintained and segregated from vehicles where necessary?
Workplace Reg 17; HSWA s2 - Is suitable slip-resistant footwear provided or required where floors cannot be kept dry and clean?
PPE Regs 1992; HSWA s2; INDG225 - Are organisational factors considered, such as work pace, rushing, overcrowding and supervision?
MHSWR Reg 3; INDG225 - Are employees provided with information and instruction on reporting spillages, defects and near misses?
HSWA s2; MHSWR Reg 10 - Are slip, trip and fall incidents and near misses reported, recorded and reviewed to identify trends and problem areas?
MHSWR Reg 5; HSWA s2 - Are control measures reviewed when circumstances change, following incidents, or where monitoring shows they are ineffective?
MHSWR Reg 3(3); INDG225
▶ Legal References
- Workplace (Health, Safety & Welfare) Regulations 1992 – Reg 12 (floors and traffic routes), Reg 17 (traffic routes), Reg 21 (lighting)
- HSWA 1974 – s2, s3
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements)
- HSE Guidance: INDG225 (Slips & Trips), HSG155 (Slips & Trips in the Workplace)
- HSE Slips Assessment Tool (SAT)
to complete