Pubs / Clubs
to complete
▶ Risks
- Electric shock from damaged or unsuitable equipment
- Fire from overloaded circuits, faulty wiring, or poor extension lead management
- Contact with live parts (poor guarding, faulty plugs, exposed wiring)
- Use of equipment in wet environments (increased shock risk)
- Trip hazards from trailing cables
- Unsafe use of multi-adaptors or daisy chains
- Damaged lighting circuits, cracked sockets, loose faceplates
- Portable appliances not maintained
- Faulty fixed wiring (old systems, missing RCDs, poorly protected circuits)
- Inadequate control of contractors working on live systems
▶ Training
- User awareness training (basic electrical hazards, visual checks)
- Training to identify damaged cables, plugs, and equipment
- Staff trained to report and isolate faulty items
- Competent electrician required for repairs and fixed wiring work
- Awareness that water + electrics increase risk
- Managers and supervisors trained to monitor cable use and overload risks
▶ Maintenance
- User visual checks before use
- PAT testing at risk-based intervals (no legal fixed frequency)
- Removal of damaged equipment from service immediately
- Fixed wiring inspection/report (EICR) by competent electrician — frequency based on risk (commonly 5 years for commercial premises)
- Routine checks of sockets, plugs, extension reels, and multi-adapters
- Ensure RCD protection where required
- Maintenance of emergency lighting and fire alarm circuits
▶ SSOW & Supervision
- Remove faulty equipment from service immediately (tag and isolate)
- No trailing or damaged cables — maintain tidy cable routing
- Do not overload sockets; avoid daisy-chaining
- Use correct equipment for damp or wet areas (IP-rated equipment)
- Ensure only competent electricians work on installations
- Provide RCD protection where reasonably practicable
- Clear procedure for reporting and dealing with electrical faults
- Supervisors monitor cable use, housekeeping, and condition of appliances
▶ Checklist
- Signs of unsafe electrical installation or equipment (e.g. exposed wires, burn marks, overheating, damaged sockets, reports of shocks)
EAWR Reg 4(1); Reg 4(2); Reg 6; HSG85 paras 7–10, 12 - Electrical equipment or installations appear damaged, poorly maintained or unsafe
EAWR Reg 4(2); Reg 6; Reg 16; HSG85 paras 8, 10, 12 - Exposed live parts or missing covers on sockets, switches, distribution boards or consumer units
EAWR Reg 4(1); Reg 14; HSG85 paras 7, 10, 14 - Electrical systems used in conditions likely to cause danger (e.g. damp environments, water ingress, unsuitable equipment for location)
EAWR Reg 4(1); Reg 4(3); HSG85 paras 12–13 - Distribution boards, fuse boxes or consumer units secure, protected and not obstructed
EAWR Reg 4(1); Reg 15; HSG85 paras 10, 15 - Means of electrical isolation provided and clearly identifiable
EAWR Reg 12; Reg 15; HSG85 paras 15, 47–49 - Electrical isolation points accessible and not locked shut or obstructed
EAWR Reg 12; Reg 15; HSG85 paras 49–52 - Portable electrical equipment appears in good condition (no damaged plugs, cables, joints or casings)
EAWR Reg 4(2); Reg 6; HSG85 paras 8, 12 - No evidence of unsafe electrical practices (e.g. trailing leads, overloaded sockets, multiple adapters, improvised wiring)
EAWR Reg 4(1); Reg 4(3); Reg 16; HSG85 paras 7, 14, 26 - Fixed electrical installations appear to be maintained so as to prevent danger
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9 - Dutyholder able to provide evidence of periodic inspection and testing of fixed electrical installations (e.g. EICR)
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9, 18
Note: HSE guidance recognises periodic inspection and testing (commonly every 5 years in many non-domestic premises, or more frequently where risk is higher) as a means of demonstrating compliance. - Evidence of inspection, testing or competent electrician involvement available where appropriate
EAWR Reg 4(2); Reg 16; HSG85 paras 18, 40–41 - Electrical work appears to be carried out by competent persons (not unqualified staff or DIY)
EAWR Reg 16; HSG85 paras 18, 40–41 - No evidence of live electrical work being carried out where it could reasonably be avoided
EAWR Reg 14; HSG85 paras 23–24
▶ Legal References
- HSWA 1974 – s2, s3 (duty to ensure electrical safety)
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- Electricity at Work Regulations 1989 – Regs 4–16 (core electrical safety duties)
- PUWER 1998 – Reg 4 (suitability), Reg 5 (maintenance), Reg 6 (inspection), Reg 9 (training)
- Workplace (Health, Safety & Welfare) Regs 1992 – Reg 12 (condition of floors/lighting)
- BS 7671 (IET Wiring Regulations) – benchmark for safe fixed installations
- HSE HSG107 & INDG236 – electrical equipment guidance (PAT, user checks)
Risks
- Falls from steps or ladders during changing lights, decorations, or signage
- Falls while accessing storage shelves, cellar racking, or high-level stock
- Falls from small platforms or stages during setup or maintenance
- Falling objects (lighting, speakers, decorations) striking staff or customers
- Unsafe use of ladders in confined or cluttered bar and cellar spaces
- Improvised access using chairs, tables, bar tops, or crates
- Slippery or uneven floors increasing ladder instability
- Working at height in low lighting or during live events
- Unsecured access to mezzanines, balconies, or DJ booths
- Lack of rescue planning when using towers or MEWPs for rigging or maintenance
Training
- Training in safe ladder and step-ladder use for bar and maintenance staff
- Training on selecting appropriate access equipment (avoid → prevent → minimise hierarchy)
- Awareness training on falling object risks during decorations or AV setup
- PASMA training where tower scaffolds are used for lighting or rigging
- IPAF or equivalent training for MEWP operators (e.g. high-level signage or lighting)
- Supervisor training to prevent unsafe improvised access
Maintenance
- Pre-use checks of ladders, steps, towers, and podiums
- Regular formal inspection of ladders and step-ladders (risk-based intervals)
- Tower scaffolds inspected after assembly, alteration, and at least every 7 days
- MEWPs maintained and subject to LOLER thorough examination where required
- Check condition of mezzanine edges, guardrails, and balcony barriers
- Ensure lighting rigs, fixings, and mounting points are secure
SSOW & Supervision
- Avoid work at height where possible (e.g. long-handled tools for cleaning/decor)
- Use podium steps or small towers instead of ladders where practicable
- Ladders only for light, short-duration tasks such as bulb changes
- Maintain 3-point contact and avoid overreaching
- Cordon off the area below when working above customer or staff areas
- Never climb on bar counters, furniture, kegs, or stacked crates
- Ensure adequate lighting when carrying out work at height
- Do not work at height during busy trading hours where practicable
- Ensure floors are dry and free from spillages before setting up access equipment
- Supervisors monitor practices and prevent unauthorised access to high areas
- Rescue arrangements in place where towers or MEWPs are used
Checklist
- Has work at height been avoided where reasonably practicable?
WAHR 2005 Reg 6(2); MHSWR Reg 3 - Has a risk assessment identified the safest method of access (avoid → prevent → minimise)?
WAHR Reg 6; MHSWR Reg 3 - Are ladders only used for light, short-duration tasks?
WAHR Reg 7 - Are ladders and steps in good condition and checked regularly?
PUWER Regs 5 & 6 - Are ladders used at the correct angle and on stable, dry surfaces?
WAHR Reg 6 - Is there 3-point contact and no overreaching?
HSE ladder guidance - Is suitable equipment (podiums, towers) provided where ladders are not adequate?
WAHR Reg 7; PUWER Reg 4 - Are edge protections or guardrails in place on mezzanines or raised areas?
WAHR Reg 8 - Are areas below work at height cordoned to protect staff and customers?
WAHR Reg 10 - Is lighting sufficient to carry out work safely?
Workplace Reg 8 - Are staff trained and supervised in safe work at height practices?
WAHR Reg 5 - Are inspections of access equipment recorded where required?
WAHR Reg 12; PUWER Reg 6
Legal References
- Work at Height Regulations 2005 – Reg 4 (planning), Reg 5 (competence), Reg 6 (avoid/prevent/minimise), Reg 7 (equipment), Reg 8 (fragile surfaces), Reg 9 (falling objects), Reg 12 (inspection)
- ACoP & Guidance L113 – Work at Height Regulations
- Health and Safety at Work etc. Act 1974 – s2, s3
- Management of Health and Safety at Work Regulations 1999 – Reg 3 (risk assessment), Reg 10 (training)
- Provision and Use of Work Equipment Regulations 1998 – Reg 4 (suitability), Reg 5 (maintenance), Reg 9 (training)
- HSE Guidance: Safe use of ladders and stepladders
Risks
- Musculoskeletal injury from lifting and moving kegs, casks, and gas cylinders
- Back injuries from handling heavy crates of drinks and stock deliveries
- Strains from repetitive handling of glasses, stock, and bar supplies
- Injuries from poor technique when working in confined cellar or bar spaces
- Crush injuries to hands or feet from dropped kegs, crates, or equipment
- Pushing and pulling injuries from moving trolleys, stillages, and waste bins
- Handling large or awkward items such as furniture, staging, or DJ equipment
- Team handling failures during deliveries or event setup
- Slips or trips while carrying loads on wet or contaminated floors
- Fatigue-related handling errors during long or busy shifts
Training
- Manual handling training specific to kegs, casks, and drinks deliveries
- Training on safe lifting techniques in confined spaces such as cellars
- Training on use of handling aids (sack trucks, keg trolleys, dollies)
- Task-specific training for moving furniture and equipment for events
- Team handling training for heavy or awkward items
- Supervisor training to identify unsafe handling practices
Maintenance
- Regular inspection of sack trucks, keg trolleys, and dollies (wheels, brakes, frames)
- Ensure cellar steps, floors, and access routes are well maintained and lit
- Maintain storage racking to reduce overreaching and awkward lifting
- Keep floors clean and dry to reduce slip/trip risks during handling
- Replace worn PPE such as gloves and slip-resistant footwear
- Review risk assessments after injuries or changes in stock/equipment
SSOW & Supervision
- Avoid manual lifting where reasonably practicable by using handling aids
- Use TILEO to assess tasks (keg weight, route, space constraints, floor condition)
- Reduce carrying distances by positioning deliveries close to storage areas
- Store heavy items at safe heights to minimise lifting from floor level
- Use team lifts for heavy or bulky items with clear communication
- Plan routes and ensure floors are dry and clear before moving loads
- Limit repetitive heavy lifting by rotating tasks where possible
- Ensure adequate staffing during large deliveries and event setups
- Supervisors monitor safe technique and use of handling aids
Checklist
- Has hazardous manual handling been avoided so far as reasonably practicable (e.g. use of keg trolleys or sack trucks)?
MHOR Reg 4(1)(a); HSWA s2; ACOP L23 - Where manual handling cannot be avoided, has a suitable and sufficient risk assessment been completed?
MHOR Reg 4(1)(b)(i); MHSWR Reg 3 - Does the assessment consider load weight, frequency, confined spaces, and floor conditions?
MHOR Reg 4; Schedule 1 - Have steps been taken to reduce risk (layout, storage height, handling aids)?
MHOR Reg 4(1)(b)(ii) - Are handling aids provided, suitable, and maintained?
MHOR Reg 4; PUWER - Are heavy kegs and crates stored to minimise lifting from floor level?
MHOR Reg 4; Schedule 1 - Is the working environment suitable (cellar access, lighting, floor condition)?
MHOR Reg 4; Schedule 1 - Are staff trained in safe techniques for the tasks they perform?
MHOR Reg 4; HSWA s2 - Are team handling arrangements in place for heavy/bulky items?
MHOR Reg 4 - Are staff provided with suitable PPE where required?
PPE Regs 1992; HSWA s2 - Are manual handling incidents and near misses reviewed?
MHSWR Reg 5; MHOR Reg 4 - Are risk assessments reviewed following incidents or changes in stock, layout, or equipment?
MHOR Reg 4(2)
Legal References
- Manual Handling Operations Regulations 1992 (as amended) – Reg 4 (avoid, assess, reduce), Reg 5 (information/training)
- Health and Safety at Work etc. Act 1974 – s2, s3
- Management of Health and Safety at Work Regulations 1999 – Reg 3 (risk assessment), Reg 13 (capabilities)
- Provision and Use of Work Equipment Regulations 1998 (PUWER)
- HSE Guidance HSG60 – Manual Handling
- INDG143 – Manual Handling at Work (HSE guide)
to complete
▶ Risks
- Contact with dangerous moving parts in glass washers, bottle crushers, ice machines and food prep equipment
- Crush or trapping injuries from cellar lifts, dumbwaiters or keg hoists (where fitted)
- Ejection of glass fragments, bottle caps, or broken components from machinery
- Mechanical failure due to poor maintenance of bar, kitchen or cellar equipment
- Unexpected start-up of cleaning machines, refrigeration plant, or cellar pumps
- Electrical hazards from portable appliances, extension leads, DJ/AV equipment and lighting rigs
- Noise exposure from entertainment equipment and sound systems during setup and maintenance
- Burns from hot surfaces such as glass washers, catering equipment, and lighting fixtures
- Poor workstation design leading to ergonomic strain (awkward reach into glass washers, low-level cellar work)
- Inadequate guarding or defeated interlocks on kitchen or bar equipment
- Use of unsuitable or damaged equipment (domestic appliances in commercial settings, overloaded extension leads)
- Risks to staff and customers from poor equipment positioning, trailing cables, or unstable fixtures
▶ Training
- Operator training on safe use of glass washers, dishwashers, ice machines and kitchen appliances
- Training on safe handling of cellar equipment (beer pumps, cooling systems, keg handling aids)
- Training on pre-use checks and recognising defects in portable electrical equipment
- Task-specific training for use of cleaning machines, compactors or bottle crushers
- Training for staff involved in setting up sound/lighting equipment or staging
- Supervisor training to monitor safe use and prevent bypassing of guards or safety devices
- Induction training covering emergency stops, isolation points and safe equipment use rules
▶ Maintenance
- Pre-use checks appropriate to the equipment (cables, plugs, guards, doors, interlocks)
- Regular inspection at risk-based intervals (PUWER Reg 6) for bar, kitchen and cellar equipment
- Preventive maintenance in line with manufacturer guidance for refrigeration, pumps, and dishwashers
- Portable appliance testing (PAT) as appropriate for electrical items
- Immediate isolation and removal from service of defective equipment
- Guarding, interlocks and safety cut-outs tested and maintained
- Functional testing of emergency stop buttons where fitted (e.g. compactors, lifts)
- Records kept of inspections and maintenance where required
▶ SSOW & Supervision
- Ensure equipment is suitable for commercial use and positioned safely (not obstructing walkways or exits)
- Maintain guarding and interlocks — zero tolerance for removal or bypass
- Use safe start/stop procedures and isolate equipment before cleaning, clearing jams or maintenance
- Keep customers and unauthorised persons away from work equipment and cellar areas
- Good housekeeping around equipment (no trailing cables, dry floors near electrical items)
- Ensure safe storage and routing of DJ/AV cables to prevent trip and equipment damage
- Use PPE where required (e.g. gloves for glass handling, hearing protection during setup work)
- Supervisors enforce safe behaviour and correct use of equipment, especially during busy periods
▶ Checklist
- Is the work equipment suitable for the task, environment and level of use in a licensed venue?
PUWER Reg 4; HSWA s2 - Has a suitable and sufficient risk assessment been carried out for risks from use of bar, cellar, kitchen and entertainment equipment?
MHSWR Reg 3; PUWER Reg 4 - Is work equipment used only for operations and under conditions for which it is suitable?
PUWER Reg 4(3) - Is work equipment maintained in efficient working order and good repair?
PUWER Reg 5 - Where deterioration could lead to danger, is work equipment inspected at appropriate intervals?
PUWER Reg 6 - Are inspection and maintenance records available where required?
PUWER Reg 6(3) - Where equipment involves specific risks (e.g. compactors, bottle crushers), is its use restricted to trained persons?
PUWER Reg 7 - Are users and supervisors provided with adequate information, instruction and training?
PUWER Regs 8 & 9; HSWA s2 - Are dangerous parts of machinery adequately guarded or otherwise protected?
PUWER Reg 11 - Are controls clearly identifiable and designed to prevent unintended operation?
PUWER Regs 14–17 - Where appropriate, are effective stop and emergency stop controls provided and functioning?
PUWER Regs 15 & 16 - Can equipment be safely isolated from energy sources for cleaning, maintenance or repair?
PUWER Reg 19 - Is equipment stable and secured where necessary?
PUWER Reg 20 - Is suitable lighting provided for safe use and maintenance of work equipment?
PUWER Reg 21 - Are appropriate markings and warnings provided and understood?
PUWER Regs 23–24 - Are employees using equipment in accordance with systems of work, training and instructions provided?
HSWA s7; PUWER Reg 9
▶ Legal References
- PUWER 1998 – Regs 4–24 (suitability, maintenance, inspection, guarding, controls, isolation)
- HSWA 1974 – s2, s3
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- ACoP L22 – Safe Use of Work Equipment
- Relevant manufacturer instructions and BS/EN standards for commercial catering, bar and entertainment equipment
Risks
- Drink spillages on floors in bar areas, dance floors, and walkways
- Broken glass and liquid residues creating slip and cut hazards
- Wet floors from cleaning, mopping, or tracked-in rainwater
- Low lighting and flashing/strobe effects reducing hazard visibility
- Trips on steps, raised areas, and changes in level near dance floors or seating zones
- Trailing cables from DJ booths, lighting rigs, speakers, and temporary AV setups
- Clutter from stools, chairs, promotional stands, and queue barriers
- Crowding and jostling leading to loss of balance
- Toilet area spillages from sinks, hand dryers, or blocked drains
- Outdoor smoking areas and entrances becoming wet, muddy, or icy
- Back-of-house hazards from kegs, deliveries, cellar access, and storage areas
- Slippery floors behind bars from constant liquid contamination
Training
- Staff training on rapid spill response and safe broken-glass cleanup
- Bar staff training on keeping behind-bar areas clean and dry
- Door and floor staff training to monitor hazards in customer areas
- Training on safe cable routing for DJs, bands, and temporary setups
- Induction training covering venue layout, steps, and emergency routes
- Training on safe manual handling of kegs and deliveries to avoid trips
- Supervisor training to coordinate floor checks during busy periods
Maintenance
- Regular inspection of floors, stairways, and dance floor surfaces
- Repair of worn flooring, loose tiles, and damaged stair nosings
- Maintain effective entrance matting to reduce water ingress
- Routine inspection of lighting including step and aisle lighting
- Maintenance of handrails on stairs and changes in level
- Inspection and upkeep of cellar steps and storage flooring
- Seasonal maintenance of external entrances and smoking areas
SSOW & Supervision
- Clean drink spills immediately using suitable methods and equipment
- Use spill kits and glass collection tools to deal with breakages safely
- Deploy signage and staff presence where floors are temporarily wet
- Keep walkways, exits, and stairs free from stools, glasses, and clutter
- Route DJ and lighting cables away from public areas or protect with covers
- Ensure step edges are clearly marked and visible in low light
- Provide and enforce slip-resistant footwear for bar and floor staff
- Increase floor monitoring during peak periods and busy events
- Manage queues to prevent overcrowding and blocked routes
- Carry out regular toilet checks to manage water and hygiene-related slip risks
- Keep cellar access routes clear and dry
- Supervisors monitor housekeeping and hazard control throughout trading hours
Checklist
-
- Has a suitable and sufficient risk assessment been completed for slip, trip and fall hazards affecting staff and customers?
MHSWR Reg 3; HSWA ss2–4; INDG225 - Does the assessment consider low lighting, crowd behaviour, and drink spillages?
MHSWR Reg 3 - Are floors suitable, well maintained, and slip resistant where contamination is frequent?
Workplace Reg 12; INDG225 - Are walkways, exits, and stairs kept free from obstructions?
Workplace Reg 12(3); HSWA s2 - Are effective arrangements in place for prompt cleanup of drink spills and broken glass?
Workplace Reg 12; INDG225 - Are cables from DJs, bands, and lighting safely routed or protected?
Workplace Reg 12(3); HSWA s2 - Are steps and changes in level clearly visible in low-light conditions?
Workplace Regs 12, 13 - Is lighting suitable and sufficient for safe movement in all accessible areas?
Workplace Reg 8 - Are toilets and wet areas managed to prevent floor contamination?
- Has a suitable and sufficient risk assessment been completed for slip, trip and fall hazards affecting staff and customers?
Workplace Reg 12
- Are external entrances and smoking areas maintained to prevent slips and trips?
Workplace Reg 12; HSWA s3 - Are staff provided with suitable slip-resistant footwear?
PPE Regs 1992; HSWA s2 - Are incidents and near misses involving slips, trips, and falls recorded and reviewed?
MHSWR Reg 5; HSWA s2 - Are control measures reviewed following incidents or changes in events or layout?
MHSWR Reg 3(3); INDG225
Legal References
- Workplace (Health, Safety & Welfare) Regulations 1992 – Reg 12 (floors and traffic routes), Reg 17 (traffic routes), Reg 8 (lighting)
- Health and Safety at Work etc. Act 1974 – s2, s3
- Management of Health and Safety at Work Regulations 1999 – Reg 3 (risk assessment), Reg 5 (arrangements)
- Personal Protective Equipment at Work Regulations 1992 (as amended)
- HSE Guidance: INDG225 (Slips & Trips), HSG155 (Slips & Trips in the Workplace)
to complete