Residential & Visitor Accommodation
▶ Main Risks
- Gas leaks from damaged hoses, faulty pipework, or poor connections
- LPG is heavier than air and can collect in basements, pits, drains, and enclosed spaces
- Carbon monoxide (CO) from poor combustion
- Inadequate ventilation leading to CO build-up or oxygen depletion
- Faulty or poorly maintained appliances
- Unsafe LPG cylinder storage or handling
- Out-of-date or damaged hoses and regulators
- Incorrect installation or unauthorised modifications
- Fire or explosion risk if gas ignites during a leak
- Staff unable to isolate gas in an emergency
- Higher-risk LPG configurations in mobile catering units
- Failure or bypassing of ventilation/gas interlock systems allowing gas appliances to operate without adequate extraction
- Build-up of unburnt gas or combustion products if extraction fails
▶ Training
- Staff awareness training on gas risks, signs of leaks, emergency actions
- Competence in safe use of appliances (lighting, shutting down, correct operation)
- Staff trained in LPG cylinder changeover (if appropriate)
- Training to recognise damaged hoses, scorched pipes, faulty regulators
- Gas Safe engineers only for installation, servicing & repairs
- CO awareness training where appliances are flued or unflued
- Staff awareness of ventilation interlock systems — understanding that gas appliances must not be used if extraction is not running
- Training to recognise interlock fault indicators or alarms
▶ Maintenance
- Annual service/safety check by Gas Safe registered engineer (industry standard)
- Regular checks on ventilation/extraction systems
- LPG hose checks (condition, date, secure crimped ends — no jubilee clips)
- Replace LPG hoses typically every 5 years (BS EN 16436-1)
- Regulator checks/replacement when out of date
- Leak testing after installation, modification or cylinder change
- Flue/extraction maintenance to ensure proper combustion
- Records kept for servicing and repairs
- Testing of gas interlock and ventilation proving systems at appropriate intervals
- Verification that gas supply automatically shuts off if mechanical ventilation fails
- Inspection and testing of airflow sensors, pressure switches and control panels
▶ SSOW & Supervision
- Clear emergency isolation procedures (staff know where shut-off valves are)
- Gas appliances used only as intended (no portable heaters in confined spaces)
- Adequate ventilation/extraction in kitchens, salons, workshops
- LPG cylinders stored upright, secure, outdoors where possible
- Only crimped or approved clip types used — no jubilee clips
- No unauthorised alterations to pipework or equipment
- Safe changeover procedures for LPG
- Supervision to ensure safe use and report defects immediately
- Gas appliances must not be used unless mechanical extraction is operating
- Interlock systems must never be overridden or bypassed
- Faults with interlocks or extraction reported and gas appliances isolated until repaired
▶ Inspection Checklist (for visits or audits)
- Signs of unsafe gas appliance operation (e.g. yellow/orange flames, soot, scorching, fumes)
GSIUR Reg 26(8) & 26(9); Reg 34(1); ACOP paras 279–280, 284(c) - Gas appliances appear damaged, poorly supported, modified or in an unsafe condition
GSIUR Reg 26(8); Reg 34(1); ACOP paras 230, 242, 280(a) - Suitable flue or extraction system provided for gas appliances and appears intact, unobstructed and operating effectively
GSIUR Reg 27; Reg 34(1); ACOP paras 279–280, 284(c) - Permanent ventilation for gas appliances present and not blocked or sealed
GSIUR Reg 27; Reg 34(1); ACOP paras 230, 279–280(a)(iii) - Emergency gas shut-off valve provided and readily accessible to the user
GSIUR Reg 9(1); ACOP paras 25–26 - Emergency gas shut-off not locked away or restricted from normal occupants
GSIUR Reg 9(1); ACOP para 25 - Disconnected gas pipework or appliances properly capped/blanked using appropriate fittings (no improvised sealing such as jubilee clips, tape or valves)
GSIUR Reg 2(1); ACOP paras 23–24 – note: Jubilee clips, tape and similar methods are not designed to seal a gasway - LPG cylinders or appliances located in basements or below ground level identified as a potential safety concern
GSIUR Reg 26(8); Reg 34(1); ACOP paras 279–280(a)(iv), 284(a) – note: LPG (propane and butane) is heavier than air. If leaked, LPG can sink and accumulate in low-level or confined spaces such as basements, cellars and pits - Dutyholder able to demonstrate that gas appliances are maintained in a safe condition (HSE guidance indicates annual checks by a Gas Safe registered engineer as a minimum in catering and hospitality premises)
GSIUR Reg 3(1); Reg 35(1); ACOP paras 230, 279–283; HSE guidance Gas safety in catering and hospitality - Mechanical ventilation system provided where required for catering gas appliances and appears operational
GSIUR Reg 26(9); Reg 27; ACOP para 257; BS 6173 - Ventilation/gas interlock system fitted where required and not bypassed or disabled
GSIUR Reg 26(9); Reg 27; BS 6173 - Evidence of testing or maintenance of interlock system available
GSIUR Reg 27; Reg 35; BS 6173
▶ Red Flags
- Jubilee / worm-drive clips on any gas hose
- Unmarked hoses (no BS / EN marking, no date)
- Perished, cracked, stiff or heat-damaged hoses
- Hoses routed through hot zones, sharp edges, or doorways
- Excessive hose length or coils (indicates poor installation)
- Hose connected directly to rigid pipe without proper connector
- Regulators mismatched to cylinder colour/type (eg propane reg on butane cylinder)
- No ID plate or marking on regulator
- Visible corrosion, damage, or oil contamination
- Regulators older than site records indicate (no replacement history)
- Improvised adapters or multiple regulators in series
▶ Legal References
- Health and Safety at Work etc. Act 1974 – s2, s3
- Management of Health and Safety at Work Regs 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- Gas Safety (Installation and Use) Regs 1998 (GSIUR) – Reg 26 (safe appliances), Reg 27 (maintenance), Reg 35 (LPG safety), Gas Safe competence requirements
- PUWER 1998 – Reg 4 (suitability), Reg 5 (maintenance), Reg 9 (training)
- Workplace (Health, Safety & Welfare) Regs 1992 – Regs 5–6 (ventilation)
- ACoP L56 – Gas Safety (Installation & Use)
- BS 6173 (commercial catering gas safety), BS EN 16436-1 (LPG hoses), LGUK Codes of Practice (LPG cylinders/mobile catering)
▶ Risks
- Electric shock from damaged or unsuitable equipment
- Fire from overloaded circuits, faulty wiring, or poor extension lead management
- Contact with live parts (poor guarding, faulty plugs, exposed wiring)
- Use of equipment in wet environments (increased shock risk)
- Trip hazards from trailing cables
- Unsafe use of multi-adaptors or daisy chains
- Damaged lighting circuits, cracked sockets, loose faceplates
- Portable appliances not maintained
- Faulty fixed wiring (old systems, missing RCDs, poorly protected circuits)
- Inadequate control of contractors working on live systems
▶ Training
- User awareness training (basic electrical hazards, visual checks)
- Training to identify damaged cables, plugs, and equipment
- Staff trained to report and isolate faulty items
- Competent electrician required for repairs and fixed wiring work
- Awareness that water + electrics increase risk
- Managers and supervisors trained to monitor cable use and overload risks
▶ Maintenance
- User visual checks before use
- PAT testing at risk-based intervals (no legal fixed frequency)
- Removal of damaged equipment from service immediately
- Fixed wiring inspection/report (EICR) by competent electrician — frequency based on risk (commonly 5 years for commercial premises)
- Routine checks of sockets, plugs, extension reels, and multi-adapters
- Ensure RCD protection where required
- Maintenance of emergency lighting and fire alarm circuits
▶ SSOW & Supervision
- Remove faulty equipment from service immediately (tag and isolate)
- No trailing or damaged cables — maintain tidy cable routing
- Do not overload sockets; avoid daisy-chaining
- Use correct equipment for damp or wet areas (IP-rated equipment)
- Ensure only competent electricians work on installations
- Provide RCD protection where reasonably practicable
- Clear procedure for reporting and dealing with electrical faults
- Supervisors monitor cable use, housekeeping, and condition of appliances
▶ Checklist
- Signs of unsafe electrical installation or equipment (e.g. exposed wires, burn marks, overheating, damaged sockets, reports of shocks)
EAWR Reg 4(1); Reg 4(2); Reg 6; HSG85 paras 7–10, 12 - Electrical equipment or installations appear damaged, poorly maintained or unsafe
EAWR Reg 4(2); Reg 6; Reg 16; HSG85 paras 8, 10, 12 - Exposed live parts or missing covers on sockets, switches, distribution boards or consumer units
EAWR Reg 4(1); Reg 14; HSG85 paras 7, 10, 14 - Electrical systems used in conditions likely to cause danger (e.g. damp environments, water ingress, unsuitable equipment for location)
EAWR Reg 4(1); Reg 4(3); HSG85 paras 12–13 - Distribution boards, fuse boxes or consumer units secure, protected and not obstructed
EAWR Reg 4(1); Reg 15; HSG85 paras 10, 15 - Means of electrical isolation provided and clearly identifiable
EAWR Reg 12; Reg 15; HSG85 paras 15, 47–49 - Electrical isolation points accessible and not locked shut or obstructed
EAWR Reg 12; Reg 15; HSG85 paras 49–52 - Portable electrical equipment appears in good condition (no damaged plugs, cables, joints or casings)
EAWR Reg 4(2); Reg 6; HSG85 paras 8, 12 - No evidence of unsafe electrical practices (e.g. trailing leads, overloaded sockets, multiple adapters, improvised wiring)
EAWR Reg 4(1); Reg 4(3); Reg 16; HSG85 paras 7, 14, 26 - Fixed electrical installations appear to be maintained so as to prevent danger
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9 - Dutyholder able to provide evidence of periodic inspection and testing of fixed electrical installations (e.g. EICR)
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9, 18
Note: HSE guidance recognises periodic inspection and testing (commonly every 5 years in many non-domestic premises, or more frequently where risk is higher) as a means of demonstrating compliance. - Evidence of inspection, testing or competent electrician involvement available where appropriate
EAWR Reg 4(2); Reg 16; HSG85 paras 18, 40–41 - Electrical work appears to be carried out by competent persons (not unqualified staff or DIY)
EAWR Reg 16; HSG85 paras 18, 40–41 - No evidence of live electrical work being carried out where it could reasonably be avoided
EAWR Reg 14; HSG85 paras 23–24
▶ Legal References
- HSWA 1974 – s2, s3 (duty to ensure electrical safety)
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- Electricity at Work Regulations 1989 – Regs 4–16 (core electrical safety duties)
- PUWER 1998 – Reg 4 (suitability), Reg 5 (maintenance), Reg 6 (inspection), Reg 9 (training)
- Workplace (Health, Safety & Welfare) Regs 1992 – Reg 12 (condition of floors/lighting)
- BS 7671 (IET Wiring Regulations) – benchmark for safe fixed installations
- HSE HSG107 & INDG236 – electrical equipment guidance (PAT, user checks)
▶ Risks
- Growth of Legionella bacteria in hot and cold water systems
- Aerosol exposure from showers, taps, spa baths and hose outlets
- Stagnation in little-used rooms or seasonal accommodation
- Dead legs or redundant pipework encouraging bacterial growth
- Incorrect water temperatures (hot not hot enough, cold not cold enough)
- Scale, sludge, corrosion and biofilm in tanks or pipework
- Poorly maintained calorifiers, pumps or circulation systems
- Contaminated storage tanks or poorly fitting lids
- Infrequent cleaning and descaling of shower heads and hoses
- Higher risk to older or immunocompromised guests
▶ Training
- Legionella awareness training for maintenance and housekeeping staff
- Training on temperature monitoring and flushing procedures
- Understanding of logbooks, monitoring schedules and escalation actions
- Responsible Person and deputy trained in water hygiene duties
- Awareness of risks associated with seasonal shutdown and reopening
▶ Maintenance
- Monthly temperature checks (hot ≥50°C at outlets, cold ≤20°C)
- Weekly flushing of little-used outlets and vacant rooms
- Quarterly cleaning and descaling of shower heads and hoses
- Annual cold water tank inspection and clean where required
- Calorifier checks including flow/return temperatures and draining of sludge
- TMV inspection, cleaning and failsafe testing
- Review of Legionella risk assessment annually or after system changes
- Logbook maintained for monitoring, checks and remedial works
▶ SSOW & Supervision
- Maintain hot water at ≥60°C in calorifiers and ≥50°C at outlets (where safe)
- Maintain cold water below 20°C where practicable
- Flush all outlets in unused rooms weekly
- Remove or minimise dead legs in pipework
- Ensure tanks are covered, insulated and screened
- Prevent aerosol exposure during maintenance tasks
- Follow the written scheme of control for monitoring and action levels
- Escalate failures (out-of-range temperatures, contamination) promptly
- Supervision to ensure checks are completed and recorded correctly
▶ Checklist
- Has a suitable and sufficient Legionella risk assessment been carried out?
COSHH Reg 6; MHSWR Reg 3; ACoP L8 paras 28–30 - Does the risk assessment include infrequently used rooms and seasonal accommodation?
ACoP L8 paras 26, 38–39 - Has a competent Responsible Person been appointed?
ACoP L8 paras 48–51 - Is there a written scheme of control for managing Legionella risks?
COSHH Reg 7; ACoP L8 paras 58–64 - Are hot and cold water temperatures monitored at appropriate frequencies?
ACoP L8 para 59(a) - Are little-used outlets flushed weekly?
ACoP L8 paras 26, 39 - Are shower heads and hoses cleaned and descaled regularly?
HSG274 Part 2 - Are storage tanks clean, covered and in good condition?
ACoP L8 para 59(e) - Are control measures maintained, examined and tested?
COSHH Reg 9; ACoP L8 paras 65–66 - Are monitoring records and logbooks maintained and reviewed?
ACoP L8 paras 70–74 - Are staff provided with suitable information and training?
COSHH Reg 12; ACoP L8 paras 49–52
▶ Legal References
- HSWA 1974 – s2, s3
- COSHH 2002 – Regs 6–13 (Legionella as a biological agent)
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- ACoP L8 – Control of Legionella Bacteria in Water Systems
- HSG274 Part 2 – Hot and Cold Water Systems
- BS 8580-1 – Legionella risk assessment guidance
Risks
- Wet floors at entrances due to rain, snow, or guests’ luggage and footwear
- Spillages of drinks and food in bedrooms, corridors, lounges, and dining areas
- Wet bathroom floors, shower overspray, and leaks
- Slippery surfaces from cleaning, polishing, or floor treatments
- Trips from luggage, housekeeping trolleys, laundry bags, and room service trays
- Loose rugs, curled carpet edges, or uneven flooring in guest rooms and corridors
- Trailing vacuum cleaner leads and cleaning equipment during housekeeping
- Poor lighting in corridors, stairwells, car parks, and external paths
- Steps, changes in level, and decorative features with limited visibility
- Slippery surfaces around swimming pools, spas, saunas, and changing areas (where provided)
- Outdoor hazards: uneven paving, gravel paths, wet leaves, ice, and moss
- Guests unfamiliar with the building layout, particularly at night
Training
- Housekeeping staff training on safe cleaning methods and spill response
- Training on safe management of cleaning equipment and trailing leads
- Front-of-house staff training to report and respond to hazards promptly
- Training on safe storage and movement of trolleys and luggage equipment
- Induction training covering internal and external high-risk areas
- Training staff to assist guests who may have mobility difficulties
- Supervisor training to monitor housekeeping standards and floor safety
Maintenance
- Regular inspection and repair of flooring, carpets, stairways, and handrails
- Ensure non-slip flooring in bathrooms, kitchens, and poolside areas
- Maintain entrance matting to control water ingress
- Routine checks of lighting in corridors, stairs, lifts, and external areas
- Repair damaged paving, loose tiles, and worn stair nosings
- Maintenance of drainage around entrances and outdoor areas
- Seasonal controls such as leaf clearance and gritting
SSOW & Supervision
- Keep corridors, stairs, and exits free from housekeeping trolleys and luggage
- Clean spills immediately and dry floors fully before allowing access
- Use signage when floors are wet and remove once safe
- Ensure bathroom floors are dried and leaks reported promptly
- Route vacuum and cleaning leads away from walkways
- Ensure good lighting is maintained, especially at night
- Secure rugs and mats to prevent movement
- Provide clear signage for changes in level or steps
- Inspect external paths and car parks regularly
- Increase monitoring during adverse weather conditions
- Supervisors monitor housekeeping and respond quickly to reported hazards
Checklist
- Has a suitable and sufficient risk assessment been completed for slip, trip and fall hazards affecting guests and staff?
MHSWR Reg 3; HSWA ss2–4; INDG225 - Are floors and traffic routes suitable, well maintained, and slip resistant where needed?
Workplace Reg 12; INDG225 - Are corridors, stairs, and exits kept clear of luggage and housekeeping equipment?
Workplace Reg 12(3); HSWA s2 - Are effective arrangements in place for prompt cleanup of spillages?
Workplace Reg 12; INDG225 - Are cleaning methods suitable and do they avoid leaving floors slippery?
INDG225 - Are entrance areas managed effectively during wet weather?
Workplace Reg 12 - Are cables from cleaning equipment safely routed?
Workplace Reg 12(3); HSWA s2 - Is lighting suitable and sufficient in all areas including stairs and external routes?
Workplace Reg 8 - Are steps, ramps, and changes in level clearly visible and fitted with suitable handrails?
Workplace Regs 12, 13 - Are bathrooms, wet rooms, and poolside areas fitted with suitable non-slip surfaces?
Workplace Reg 12(2) - Are external paths, car parks, and access routes maintained to prevent slips and trips?
Workplace Reg 12; HSWA s3 - Are slip, trip and fall incidents and near misses recorded and reviewed?
MHSWR Reg 5; HSWA s2 - Are control measures reviewed following incidents or changes in layout or occupancy?
MHSWR Reg 3(3); INDG225
Legal References
- Workplace (Health, Safety & Welfare) Regulations 1992 – Reg 12 (floors and traffic routes), Reg 17 (traffic routes), Reg 8 (lighting)
- Health and Safety at Work etc. Act 1974 – s2, s3
- Management of Health and Safety at Work Regulations 1999 – Reg 3 (risk assessment), Reg 5 (arrangements)
- HSE Guidance: INDG225 (Slips & Trips), HSG155 (Slips & Trips in the Workplace)