Supported living
▶ Risks
- Electric shock from damaged or unsuitable equipment
- Fire from overloaded circuits, faulty wiring, or poor extension lead management
- Contact with live parts (poor guarding, faulty plugs, exposed wiring)
- Use of equipment in wet environments (increased shock risk)
- Trip hazards from trailing cables
- Unsafe use of multi-adaptors or daisy chains
- Damaged lighting circuits, cracked sockets, loose faceplates
- Portable appliances not maintained
- Faulty fixed wiring (old systems, missing RCDs, poorly protected circuits)
- Inadequate control of contractors working on live systems
▶ Training
- User awareness training (basic electrical hazards, visual checks)
- Training to identify damaged cables, plugs, and equipment
- Staff trained to report and isolate faulty items
- Competent electrician required for repairs and fixed wiring work
- Awareness that water + electrics increase risk
- Managers and supervisors trained to monitor cable use and overload risks
▶ Maintenance
- User visual checks before use
- PAT testing at risk-based intervals (no legal fixed frequency)
- Removal of damaged equipment from service immediately
- Fixed wiring inspection/report (EICR) by competent electrician — frequency based on risk (commonly 5 years for commercial premises)
- Routine checks of sockets, plugs, extension reels, and multi-adapters
- Ensure RCD protection where required
- Maintenance of emergency lighting and fire alarm circuits
▶ SSOW & Supervision
- Remove faulty equipment from service immediately (tag and isolate)
- No trailing or damaged cables — maintain tidy cable routing
- Do not overload sockets; avoid daisy-chaining
- Use correct equipment for damp or wet areas (IP-rated equipment)
- Ensure only competent electricians work on installations
- Provide RCD protection where reasonably practicable
- Clear procedure for reporting and dealing with electrical faults
- Supervisors monitor cable use, housekeeping, and condition of appliances
▶ Checklist
- Signs of unsafe electrical installation or equipment (e.g. exposed wires, burn marks, overheating, damaged sockets, reports of shocks)
EAWR Reg 4(1); Reg 4(2); Reg 6; HSG85 paras 7–10, 12 - Electrical equipment or installations appear damaged, poorly maintained or unsafe
EAWR Reg 4(2); Reg 6; Reg 16; HSG85 paras 8, 10, 12 - Exposed live parts or missing covers on sockets, switches, distribution boards or consumer units
EAWR Reg 4(1); Reg 14; HSG85 paras 7, 10, 14 - Electrical systems used in conditions likely to cause danger (e.g. damp environments, water ingress, unsuitable equipment for location)
EAWR Reg 4(1); Reg 4(3); HSG85 paras 12–13 - Distribution boards, fuse boxes or consumer units secure, protected and not obstructed
EAWR Reg 4(1); Reg 15; HSG85 paras 10, 15 - Means of electrical isolation provided and clearly identifiable
EAWR Reg 12; Reg 15; HSG85 paras 15, 47–49 - Electrical isolation points accessible and not locked shut or obstructed
EAWR Reg 12; Reg 15; HSG85 paras 49–52 - Portable electrical equipment appears in good condition (no damaged plugs, cables, joints or casings)
EAWR Reg 4(2); Reg 6; HSG85 paras 8, 12 - No evidence of unsafe electrical practices (e.g. trailing leads, overloaded sockets, multiple adapters, improvised wiring)
EAWR Reg 4(1); Reg 4(3); Reg 16; HSG85 paras 7, 14, 26 - Fixed electrical installations appear to be maintained so as to prevent danger
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9 - Dutyholder able to provide evidence of periodic inspection and testing of fixed electrical installations (e.g. EICR)
EAWR Reg 4(2); Reg 6; HSG85 paras 8–9, 18
Note: HSE guidance recognises periodic inspection and testing (commonly every 5 years in many non-domestic premises, or more frequently where risk is higher) as a means of demonstrating compliance. - Evidence of inspection, testing or competent electrician involvement available where appropriate
EAWR Reg 4(2); Reg 16; HSG85 paras 18, 40–41 - Electrical work appears to be carried out by competent persons (not unqualified staff or DIY)
EAWR Reg 16; HSG85 paras 18, 40–41 - No evidence of live electrical work being carried out where it could reasonably be avoided
EAWR Reg 14; HSG85 paras 23–24
▶ Legal References
- HSWA 1974 – s2, s3 (duty to ensure electrical safety)
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- Electricity at Work Regulations 1989 – Regs 4–16 (core electrical safety duties)
- PUWER 1998 – Reg 4 (suitability), Reg 5 (maintenance), Reg 6 (inspection), Reg 9 (training)
- Workplace (Health, Safety & Welfare) Regs 1992 – Reg 12 (condition of floors/lighting)
- BS 7671 (IET Wiring Regulations) – benchmark for safe fixed installations
- HSE HSG107 & INDG236 – electrical equipment guidance (PAT, user checks)
▶ Risks
- Growth of Legionella bacteria in hot and cold water systems
- Aerosol exposure from showers, taps, baths and hose outlets
- Higher vulnerability of residents (older age, underlying health conditions, immunocompromised)
- Stagnation in little-used rooms, spare bathrooms or redundant outlets
- Dead legs and complex pipework increasing stagnation risk
- Incorrect water temperatures (hot not hot enough, cold not cold enough)
- Scale, sludge, corrosion and biofilm in tanks, calorifiers and distribution pipework
- Poorly maintained TMVs (impacting safe temperatures at outlets and increasing stagnation if poorly configured)
- Infrequent cleaning and descaling of shower heads and hoses
- Failure of pumps, calorifiers or circulation leading to reduced flow and stagnation
▶ Training
- Legionella awareness training for maintenance, housekeeping and relevant care staff
- Training on temperature monitoring, flushing routines and escalation actions
- Training for the Responsible Person and deputy (roles, authority, record keeping)
- Awareness of the balance between Legionella control and scald prevention (TMVs and outlet temperatures)
- Competence in water sampling where undertaken (typically by competent contractors)
- Understanding of logbooks, monitoring schedules and how to report defects promptly
▶ Maintenance
- Monthly temperature monitoring (typical targets: hot ≥50°C at outlets, cold ≤20°C; adjusted where TMVs are used)
- Weekly flushing of little-used outlets (e.g. vacant rooms, seldom-used bathrooms)
- Quarterly cleaning and descaling of shower heads and hoses
- Annual cold water storage tank inspection and internal clean where required
- Calorifier checks (flow/return temperatures, drain/flush to remove sludge)
- TMV maintenance and failsafe testing to manage scald risk while maintaining system control
- Inspection/maintenance of circulation pumps and pipework insulation
- Review of risk assessment at least annually and after system changes, outbreaks or control failures
- Records/logbook maintained and reviewed regularly
▶ SSOW & Supervision
- Maintain hot water storage at ≥60°C at calorifiers (where practicable) and cold water below 20°C where possible
- Use TMVs appropriately to reduce scald risk at outlets while maintaining effective hot water storage temperatures
- Flush low-use outlets weekly and manage vacant rooms to avoid stagnation
- Keep tanks covered, insulated and clean; ensure screened overflows/vents where fitted
- Remove dead legs and redundant pipework where reasonably practicable
- Ensure good circulation (balanced system and working pumps)
- Follow a written scheme of control, including monitoring frequencies and action levels
- Escalate failures promptly (out-of-range temperatures, contamination, poor circulation, defects)
- Supervise checks and verify logbook accuracy; management review of trends and repeat failures
- Control aerosol release during maintenance (e.g. careful shower head removal/cleaning)
▶ Checklist
- Has a suitable and sufficient Legionella risk assessment been carried out?
COSHH Reg 6; MHSWR Reg 3; HSWA ss2–4; ACoP L8 paras 28–30 - Does the risk assessment cover all outlets, including vacant rooms, little-used bathrooms and dead legs?
ACoP L8 paras 26, 38–39 - Is the risk assessment reviewed regularly and when circumstances change (system changes, failures, incidents)?
COSHH Reg 6; ACoP L8 paras 32, 47 - Has a competent person been appointed to manage and control Legionella risks (Responsible Person)?
COSHH Reg 8; ACoP L8 paras 48–51 - Does the Responsible Person have sufficient authority, competence and training?
ACoP L8 paras 48–51 - Where there is a reasonably foreseeable risk, is there a written scheme of control in place?
COSHH Reg 7; ACoP L8 paras 58–64 - Are measures in place to avoid water temperatures between 20–45°C where practicable (system-wide control)?
COSHH Reg 7; ACoP L8 para 59(a) - Are measures in place to prevent stagnation, including flushing routines and control/removal of dead legs?
ACoP L8 paras 26, 39, 59(b) - Is the water system kept clean and properly maintained (tanks, calorifiers, outlets, shower heads)?
COSHH Reg 7; ACoP L8 paras 59(e), 61–63 - Are routine inspections and monitoring carried out at appropriate intervals, and results reviewed?
COSHH Reg 9; ACoP L8 paras 65–66, 69 - Are remedial actions taken promptly where monitoring indicates control failure?
COSHH Reg 7; ACoP L8 paras 62(e), 69 - Are staff provided with suitable information, instruction and training on Legionella risks and controls?
COSHH Reg 12; HSWA s2; ACoP L8 paras 49–52 - Are contractors and service providers competent and properly managed?
HSWA s3; ACoP L8 paras 57, 75–83 - Are records kept of risk assessment, written scheme, monitoring, inspections and remedial works?
COSHH Reg 9; ACoP L8 paras 70–74 - Are records retained for required periods (minimum two years; monitoring records five years)?
ACoP L8 para 72 - Are cases of legionellosis reported under RIDDOR where criteria are met?
RIDDOR 2013; ACoP L8 para 18
▶ Legal References
- HSWA 1974 – s2, s3
- COSHH 2002 – Legionella as a biological agent (Reg 6 risk assessment, Reg 7 prevention/control, Reg 9 maintenance/examination/testing, Reg 12 training)
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- ACoP L8 – Legionnaires’ Disease: The control of Legionella bacteria in water systems
- HSG274 Parts 1–3 – Technical guidance for hot & cold water, cooling and other systems
- BS 8580-1 – Legionella risk assessment guidance
Risks
- Musculoskeletal injury from supporting or transferring residents
- Back injuries from moving or repositioning people in beds or chairs
- Strains from pushing wheelchairs, beds, and mobile equipment
- Injuries from poor posture when working in confined spaces (bedrooms, bathrooms)
- Sudden movement by residents leading to loss of balance or awkward loads
- Crush or trapping injuries when using hoists, slings, or profiling beds
- Team handling failures during complex transfers
- Slips or trips while assisting residents, especially in bathrooms or wet areas
- Fatigue from repeated handling tasks across shifts
- Injuries caused by inappropriate or poorly fitted slings and equipment
Training
- Manual handling and people-moving training tailored to care environments
- Training on use of hoists, slings, transfer boards, slide sheets, and stand aids
- Training in assessing resident mobility and selecting appropriate techniques
- Refresher training to reinforce safe techniques and update on equipment changes
- Team handling training for complex or bariatric transfers
- Training supervisors to assess staff competence and safe practice
Maintenance
- Regular inspection and servicing of hoists, stand aids, slings, and transfer equipment
- Ensure slings are correctly sized, labelled, and in good condition
- Maintenance of profiling beds, bed rails, and mobility aids
- Ensure wheels, brakes, and frames of wheelchairs and trolleys are maintained
- Keep floors, corridors, and bedrooms free of obstructions to allow safe manoeuvring
- Replace worn PPE such as gloves and slip-resistant footwear
- Review handling equipment suitability when residents’ needs change
SSOW & Supervision
- Avoid manual lifting of people wherever reasonably practicable by using hoists and aids
- Use individual moving and handling care plans for each resident
- Assess each transfer using TILE principles before starting
- Ensure sufficient trained staff are present for the task
- Check equipment and sling compatibility before use
- Communicate clearly with the resident and other staff during transfers
- Position equipment to minimise reaching, twisting, and overexertion
- Plan routes before moving residents in beds or wheelchairs
- Stop if conditions are unsafe (clutter, poor lighting, wet floors)
- Supervisors monitor handling practices and staff wellbeing
Checklist
- Has hazardous manual handling of residents been avoided so far as reasonably practicable through use of mechanical aids?
MHOR Reg 4(1)(a); HSWA s2 - Where manual handling cannot be avoided, has a suitable and sufficient risk assessment been completed?
MHOR Reg 4(1)(b)(i); MHSWR Reg 3 - Are individual moving and handling care plans in place and up to date?
MHOR Reg 4; Schedule 1 - Are hoists, slings, and other aids provided, suitable, and used correctly?
MHOR Reg 4(1)(b)(ii); LOLER; PUWER - Are sufficient trained staff available for team handling tasks?
MHOR Reg 4; HSWA s2 - Are residents’ individual capabilities and health conditions considered?
MHOR Reg 4(3) - Is the working environment suitable (space, floor condition, lighting, temperature)?
MHOR Reg 4; Schedule 1 - Is equipment inspected, maintained, and thoroughly examined as required?
LOLER; PUWER - Have staff received task-specific training in people handling and equipment use?
MHOR Reg 4; HSWA s2 - Are staff physically capable and fit for the tasks they undertake?
MHSWR Reg 13 - Are manual handling incidents and near misses reviewed to identify trends?
MHOR Reg 4; MHSWR Reg 5 - Are risk assessments and care plans reviewed when residents’ needs change or after incidents?
MHOR Reg 4(2)
Legal References
- Manual Handling Operations Regulations 1992 (as amended) – Reg 4 (avoid, assess, reduce), Reg 5 (information/training)
- Health and Safety at Work etc. Act 1974 – s2, s3
- Management of Health and Safety at Work Regulations 1999 – Reg 3 (risk assessment), Reg 13 (capabilities)
- Lifting Operations and Lifting Equipment Regulations 1998 (LOLER)
- Provision and Use of Work Equipment Regulations 1998 (PUWER)
- HSE Guidance HSG60 – Manual Handling
- INDG143 – Manual Handling at Work (HSE guide)
▶ Risks
- Crush or trapping injuries from profiling beds, bed rails, hoists and adjustable bathing equipment
- Entrapment or entanglement risks associated with moving parts on hoists, slings and transfer aids
- Struck-by injuries from falling items on poorly secured trolleys, linen skips or mobile equipment
- Mechanical failure due to poor maintenance of hoists, beds or bathing systems
- Unexpected movement or start-up of powered beds, hoists or chairs during cleaning or maintenance
- Electrical hazards from portable appliances in care and wet areas (hoists, bath lifts, cleaning equipment)
- Burns from hot water, heated cabinets or kitchen/catering equipment within the home
- Poor workstation design causing ergonomic strain (awkward positioning of beds, low-level tasks)
- Inadequate guarding or missing safety features on equipment such as laundry or kitchen machinery
- Use of unsuitable or damaged equipment for service user needs (incorrect sling type/size)
- Risks to residents, staff and visitors from poorly positioned equipment or trailing cables
▶ Training
- Training on safe use of hoists, slings, transfer aids and adjustable beds
- Training on safe use of bath lifts, shower trolleys and other care equipment
- Training on pre-use checks and defect reporting
- Task-specific training for laundry and kitchen equipment where used
- Training on safe cleaning and isolation before maintenance
- Supervisor training to monitor compliance and prevent misuse of equipment
- Induction training covering emergency stops, isolation points and safe equipment practices
▶ Maintenance
- Pre-use checks appropriate to the equipment (hoist straps, bed controls, brakes, cables)
- Regular inspection at risk-based intervals (PUWER Reg 6) for care and support equipment
- Preventive maintenance in line with manufacturer guidance
- Portable appliance testing (PAT) where appropriate
- Immediate isolation and removal from service of defective equipment
- Guarding, interlocks and safety features tested and maintained
- Inspection and maintenance of lifting mechanisms on beds and bathing equipment
- Records kept of inspections and maintenance where required
▶ SSOW & Supervision
- Ensure equipment is suitable for the individual’s needs and care plan
- Position equipment safely with clear access and minimal trip hazards
- Maintain safety features — do not bypass bed rails, interlocks or hoist safety systems
- Use safe start/stop procedures and isolate equipment before cleaning or maintenance
- Keep residents and visitors away from equipment during servicing or adjustment
- Good housekeeping around equipment (no trailing cables, clear floors, safe storage)
- Use PPE where required (e.g. gloves for cleaning or maintenance tasks)
- Supervisors monitor safe behaviour and correct equipment use in line with care plans
▶ Checklist
- Is the work equipment suitable for the task, environment and individual care needs?
PUWER Reg 4; HSWA s2 - Has a suitable and sufficient risk assessment been carried out for risks from care equipment use?
MHSWR Reg 3; PUWER Reg 4 - Is equipment used only under conditions for which it is suitable?
PUWER Reg 4(3) - Is equipment maintained in efficient working order and good repair?
PUWER Reg 5 - Where deterioration could lead to danger, is equipment inspected at appropriate intervals?
PUWER Reg 6 - Are inspection and maintenance records available where required?
PUWER Reg 6(3) - Where equipment involves specific risks (e.g. hoists, profiling beds), is its use restricted to trained persons?
PUWER Reg 7 - Are users and supervisors provided with adequate information, instruction and training?
PUWER Regs 8 & 9; HSWA s2 - Are dangerous parts of machinery adequately guarded or otherwise protected?
PUWER Reg 11 - Are controls clearly identifiable and designed to prevent unintended operation?
PUWER Regs 14–17 - Are effective stop and emergency stop controls provided and functioning where appropriate?
PUWER Regs 15 & 16 - Can equipment be safely isolated from energy sources for maintenance and cleaning?
PUWER Reg 19 - Is equipment stable and secured where necessary?
PUWER Reg 20 - Is suitable lighting provided for safe use and maintenance of equipment?
PUWER Reg 21 - Are appropriate markings and warnings provided and understood?
PUWER Regs 23–24 - Are employees using equipment in accordance with systems of work, training and instructions provided?
HSWA s7; PUWER Reg 9
▶ Legal References
- PUWER 1998 – Regs 4–24 (suitability, maintenance, inspection, guarding, controls, isolation)
- HSWA 1974 – s2, s3
- MHSWR 1999 – Reg 3 (risk assessment), Reg 5 (arrangements), Reg 10 (training)
- ACoP L22 – Safe Use of Work Equipment
- Manufacturer guidance and relevant BS/EN standards for care and lifting equipment
Risks
- Spillages of drinks, food, or bodily fluids in bedrooms, lounges, and dining areas
- Wet floors in bathrooms, wet rooms, shower areas, and near hand basins
- Incontinence-related contamination creating unexpected slip hazards
- Trailing medical equipment leads, hoist charging cables, and mobility aid accessories
- Clutter from mobility aids, wheelchairs, walking frames, and personal belongings
- Loose rugs, mats, and curled carpet edges in homely environments
- Poor lighting in bedrooms at night, corridors, and stairways
- Residents mobilising without support, especially those with dementia, poor balance, or impaired vision
- Footwear issues, including ill-fitting slippers or walking in socks
- Changes in level such as thresholds, ramps, or steps between areas
- Wet entrance floors from visitors, deliveries, or outdoor access
- Outdoor hazards in gardens and paths: uneven paving, moss, leaves, ice, and mud
- Trips during moving and handling activities involving hoists, slings, and equipment
Training
- Staff training on prompt spill response and safe cleaning methods in occupied areas
- Training on safe management of bodily fluid spillages and infection control cleaning
- Moving and handling training to reduce loss of balance during transfers and support
- Training to recognise individual fall risk factors (mobility, cognition, medication effects)
- Induction training covering housekeeping standards and safe storage of equipment
- Training staff to encourage safe footwear and appropriate clothing for residents
- Supervisor training to monitor environmental safety and residents’ changing needs
Maintenance
- Regular inspection of flooring, carpets, thresholds, and stairways
- Repair or replacement of damaged flooring, loose tiles, and worn anti-slip surfaces
- Ensure non-slip flooring in bathrooms, wet rooms, and high-risk areas
- Maintain handrails, grab rails, and stair rails in good condition
- Ensure adequate lighting, including night lighting in bedrooms and corridors
- Maintain entrance matting and external paths to prevent water ingress and slips
- Routine checks of hoists, beds, trolleys, and mobility equipment to ensure safe movement
SSOW & Supervision
- Keep corridors, bedrooms, and communal areas free from clutter and unnecessary furniture
- Clean spills immediately and dry floors thoroughly before allowing access
- Use discreet signage or staff supervision where floors are temporarily wet
- Store mobility aids and equipment safely without blocking walkways
- Ensure cables from medical or electrical equipment are routed safely
- Encourage and support residents to wear well-fitting, slip-resistant footwear
- Ensure residents who are high fall risk have appropriate supervision or mobility aids
- Provide adequate lighting at night to support safe movement to bathrooms
- Check floors during and after personal care tasks that may cause splashing
- Carry out environmental safety checks each shift, including bedrooms and bathrooms
- Ensure outdoor areas are inspected before use and unsafe areas restricted
- Supervisors monitor both environmental hazards and residents’ changing fall risk
Checklist
- Has a suitable and sufficient risk assessment been carried out for slip, trip and fall hazards affecting residents, staff, and visitors?
MHSWR Reg 3; HSWA ss2–4; INDG225 - Are individual fall risk assessments in place for residents, considering mobility, cognition, medication, and vision?
MHSWR Reg 3; Care Standards guidance - Are floors and surfaces suitable, well maintained, and slip resistant where required (especially bathrooms and wet rooms)?
Workplace Reg 12; INDG225 - Are corridors, bedrooms, and communal areas kept free from obstructions and clutter?
Workplace Reg 12(3); HSWA s2 - Are effective arrangements in place for prompt cleaning of spills and bodily fluids?
Workplace Reg 12; INDG225 - Are cables from medical or electrical equipment routed safely to prevent trips?
Workplace Reg 12(3); HSWA s2 - Is lighting suitable and sufficient, including night lighting for safe movement?
Workplace Reg 8 - Are handrails, grab rails, and mobility supports provided where needed and well maintained?
Workplace Regs 12, 13 - Are entrance areas managed effectively to reduce wet floor risks?
Workplace Reg 12; INDG225 - Are external paths and garden areas maintained to prevent slips and trips?
Workplace Reg 12; HSWA s3 - Are staff provided with suitable footwear where floors may be contaminated?
PPE Regs 1992; HSWA s2 - Are slips, trips, falls, and near misses recorded and reviewed to identify trends?
MHSWR Reg 5; HSWA s2 - Are control measures reviewed when residents’ needs change or after incidents?
MHSWR Reg 3(3); INDG225
Legal References
- Workplace (Health, Safety & Welfare) Regulations 1992 – Reg 12 (floors and traffic routes), Reg 17 (traffic routes), Reg 8 (lighting)
- Health and Safety at Work etc. Act 1974 – s2, s3
- Management of Health and Safety at Work Regulations 1999 – Reg 3 (risk assessment), Reg 5 (arrangements)
- Manual Handling Operations Regulations 1992 (as amended)
- HSE Guidance: INDG225 (Slips & Trips), HSG155 (Slips & Trips in the Workplace)
to complete